Measurement of squeeze flow field in a bi-leaflet mechanical heart valve model

被引:0
|
作者
Zhao, J. [1 ]
Yeo, J.H. [1 ]
Hwang, N.H.C. [2 ]
机构
[1] Nanyang Technological University, Singapore, Singapore
[2] University of Miami
关键词
All Open Access; Bronze;
D O I
10.1097/00002480-200003000-00145
中图分类号
学科分类号
摘要
Heart valve prostheses
引用
收藏
相关论文
共 50 条
  • [1] Peak Flow in Model Aorta Through Bi-Leaflet Mechanical Heart Valve with Varying Orientation
    Satheesh, Kumar H.
    Sharma, Shailendra D.
    ASAIO JOURNAL, 2021, 67 (07) : 757 - 768
  • [2] Simulation of Blood flow in Different Configurations Design of Bi-leaflet Mechanical Heart Valve
    Mokhtar, N. Hafizah
    Abas, Aizat
    INTERNATIONAL CONFERENCE ON AEROSPACE AND MECHANICAL ENGINEERING (AEROMECH17), 2018, 370
  • [3] CFD investigation of steady flow in bi-leaflet heart valve hinge
    Wang, JH
    Yeo, TJH
    Lim, CS
    CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2000, 28 (1-2) : 61 - 67
  • [4] THE EFFECTS OF FLUID PROPERTIES AND FLOW CONDITIONS ON LOCAL BI-LEAFLET MECHANICAL HEART VALVE HEMODYNAMICS
    Herbertson, L. H.
    Deutsch, S.
    Manning, K. B.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 584 - 584
  • [5] CFD investigation of steady flow in bi-leaflet heart valve hinge
    Wang, J.H.
    Yeo, J.H.
    Chu, C.S.
    Critical Reviews in Biomedical Engineering, 1998, 26 (05): : 303 - 304
  • [6] Analysis of mechanical bi-leaflet heart valve made of biomaterial-polypropylene
    Kumar, D. Suresh
    Thammu, R. A. K. E. S. H.
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 4411 - 4418
  • [7] A comparative study of Newtonian and non-Newtonian blood flow through Bi-Leaflet Mechanical Heart Valve
    Sarkar, Nandan
    Sharma, Siddharth D.
    Chakraborty, Suman
    Roy, Somnath
    COMPUTERS & FLUIDS, 2024, 279
  • [8] Hemodynamic Effects of the Orientation of a Bi-leaflet Mechanical Heart Valve Implanted in an Anatomic Aorta
    Borazjani, I.
    Le, T.
    Sotiropoulos, F.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1230 - 1233
  • [9] THE DUROMEDICS BI-LEAFLET (HEART) VALVE - A POST IMPLANTATION STUDY
    DEAL, CW
    THORACIC AND CARDIOVASCULAR SURGEON, 1985, 33 : 78 - 78
  • [10] INFLUENCE OF THE MECHANICAL BI-LEAFLET PROSTHETIC VALVE DESIGNS ON THE FLOW FIELD AND ACCUMULATED STRESS INSIDE THE SIMULATED AORTA
    Akutsu, T.
    Takahashi, H.
    Kamoshita, Y.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 668 - 668