One-fifteenth scale model of the prestressed concrete containment vessel (CCV) for 1100 MWe PWR type reactor was tested under high inner pressure and temperature simulating loss of coolant accident and under horizontal stress imitating earthquake. Ultimate horizontal load sustained by the CCV was 648 tons which is 2. 7 times more than the stress produced by an earthquake.