Encapsulated FBG temperature sensor without load influence

被引:0
|
作者
Wang, He-Zhe [1 ]
Zhou, Zhi [1 ]
Ou, Jin-Ping [1 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
关键词
Calibration - Encapsulation - Fiber Bragg gratings - Loading - Monitoring - Optical fibers - Temperature;
D O I
暂无
中图分类号
学科分类号
摘要
Common FBG sensor is easily influenced by load while it is used in the rude construction of infrastructures, which can result in errors, even undermine the monitoring system. A new kind of encapsulated FBG temperature sensor without load influence is brought forward. The experiments of sensitivity coefficient calibration arid loading have been carried out. And the sensing properties of such kind of encapsulated FBG temperature sensors filled with and without good thermal transfer material has also been compared. The results show that the temperature-sensing coefficient of the new kind of sensor is almost the same as the bare one and the linearity is 0.999. The encapsulated FBG temperature sensor filled with thermal transfer material can sense the temperature easier than the other ones, and the temperature-seising coefficient keep the same. Moreover, the encapsulated FBG temperature sensor's wavelength is not changed under load of 80 N.
引用
收藏
页码:68 / 70
相关论文
共 50 条
  • [1] Temperature Compensated Transverse Load Sensor Based On Dual Fbg Sensor
    Pant, Jayshreekar
    Mitra, Anupam
    Tiwari, Umesh
    Mondal, Samir
    Singh, Nahar
    Jain, Subhash
    Kapur, Pawan
    INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN MICROWAVE THEORY AND APPLICATIONS, PROCEEDINGS, 2008, : 395 - +
  • [2] FBG sensor of breathing encapsulated into polydimethylsiloxane
    Fajkus, Marcel
    Nedoma, Jan
    Siska, Petr
    Vasinek, Vladimir
    OPTICAL MATERIALS AND BIOMATERIALS IN SECURITY AND DEFENCE SYSTEMS TECHNOLOGY XIII, 2016, 9994
  • [3] A simple passive temperature-independent FBG load sensor
    Hao, J.
    Cai, Z.
    Ng, J. H.
    Gong, Y.
    Maniyeri, J.
    Foo, S. F.
    Yee, Nling-Li
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 232 - 233
  • [4] Cardiac monitoring with a smart textile based on polymer-encapsulated FBG: influence of sensor positioning
    Lo Presti, Daniela
    Massaroni, Carlo
    Di Tocco, Joshua
    Schena, Emiliano
    Formica, Domenico
    Caponero, Michele Arturo
    Longo, Umile Giuseppe
    Carnevale, Arianna
    D'Abbraccio, Jessica
    Massari, Luca
    Oddo, Calogero
    2019 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2019,
  • [5] Comparison of the FBG sensor encapsulated into PDMS and FBG sensor glued on the plexiglass pad for respiratory and heart rate monitoring
    Fajkus, Marcel
    Nedoma, Jan
    Martinek, Radek
    Walendziuk, Wojciech
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH ENERGY PHYSICS EXPERIMENTS 2017, 2017, 10445
  • [6] Sensitivity enhancement of FBG temperature sensor
    Kang, HanChul
    Kim, Daegil
    Song, Minho
    OPTICAL SENSING AND DETECTION II, 2012, 8439
  • [7] The influence of FBG on Brillouin distributed sensor
    Li J.
    Sun B.
    Kinzo K.
    Journal of Civil Structural Health Monitoring, 2015, 5 (05) : 629 - 643
  • [8] THE STUDY OF ENHANCING TEMPERATURE SENSITIVITY FOR FBG TEMPERATURE SENSOR
    Li, Wei
    Li, Yong-Wei
    Han, Xing-De
    Yu, Guo-Qing
    PROCEEDINGS OF 2009 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-6, 2009, : 2746 - +
  • [9] Design of Humidity and Temperature Sensor Based on FBG
    Wang, ShouHua
    Zhang, Bo
    2016 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C), 2016, : 646 - 647
  • [10] FBG-based temperature sensor package
    Reddy, M. Venkata
    Prasad, R. L. N. Sai
    Srimannarayana, K.
    Manohar, M.
    Apparao, T. V.
    2014 9TH INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (ICIIS), 2014, : 370 - 373