Efficient position sensitive detector for 3-30 keV positrons and electrons

被引:0
|
作者
Schmidt, P.V. [1 ]
Willmann, L. [1 ]
Abela, R. [1 ]
Bagaturia, J. [1 ]
Bertl, W. [1 ]
Braun, B. [1 ]
Folger, H. [1 ]
Jungmann, K. [1 ]
Mzavia, D. [1 ]
zu Putlitz, G. [1 ]
Renker, D. [1 ]
Sakhelashvilli, T. [1 ]
Zhang, L. [1 ]
机构
[1] Universitaet Heidelberg, Heidelberg, Germany
关键词
We are grateful to R. Rusnyak of the Physikalisches Institut der Universitlt Heidelberg for help with developing charge integrating preamplifiers. We appreciate the high quality C foils provided by W. Thalheimer of GSI Darmstadt.D uring the experimentsw e have received great hospitality and support from all the memberso f PSI. This work has been supported by the German BMBF and a NATO researchg rant;
D O I
暂无
中图分类号
学科分类号
摘要
15
引用
收藏
页码:139 / 145
相关论文
共 50 条
  • [1] An efficient position sensitive detector for 3-30 keV positrons and electrons
    Schmidt, PV
    Willmann, L
    Abela, R
    Bagaturia, J
    Bertl, W
    Braun, B
    Folger, H
    Jungmann, K
    Mzavia, D
    Putlitz, GZ
    Renker, D
    Sakhelashvilli, T
    Zhang, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 376 (01): : 139 - 145
  • [2] POSITION-SENSITIVE DETECTOR FOR ELECTRONS
    MOAK, CD
    DATZ, S
    GARCIASANTIBANEZ, F
    CARLSON, TA
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1975, 6 (02) : 151 - 156
  • [3] Time and position sensitive photon detector for coincidence measurements in the keV energy range
    Ismail, Iyas
    Journel, Loic
    Vacheresse, Regis
    Palaudoux, Jerome
    Marin, Thierry
    Penent, Francis
    Simon, Marc
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (11):
  • [4] Sequence-specific damage induced by the impact of 3-30 eV electrons on oligonucleotides
    Abdoul-Carime, H
    Sanche, L
    RADIATION RESEARCH, 2001, 156 (02) : 151 - 157
  • [5] Characterisation of the Medipix3 detector for 60 and 80 keV electrons
    Mir, J. A.
    Clough, R.
    MacInnes, R.
    Gough, C.
    Plackett, R.
    Shipsey, I.
    Sawada, H.
    MacLaren, I.
    Ballabriga, R.
    Maneuski, D.
    O'Shea, V.
    McGrouther, D.
    Kirkland, A. I.
    ULTRAMICROSCOPY, 2017, 182 : 44 - 53
  • [6] A POSITION-SENSITIVE MICROCHANNEL-PLATE DETECTOR FOR 27-KEV IONS
    ZHANG, YJ
    WEI, YQ
    WANG, QY
    QIAN, WG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01): : 76 - 82
  • [7] POSITION-SENSITIVE DETECTOR FOR HEAVY ATOMIC PARTICLES IN KEV ENERGY-RANGE
    OLSEN, JO
    NUCLEAR INSTRUMENTS & METHODS, 1977, 140 (01): : 29 - 35
  • [8] Position-sensitive microchannel-plate detector for 27-keV ions
    Zhang, Yingji
    Wei, Yongqin
    Wang, Qiuyu
    Qian, Wenguo
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991, A302 (01):
  • [9] Detector for Detection of Electrons with an Energy of 5–30 keV for the “Troitsk Nu-Mass” Setup
    P. N. Aruev
    A. I. Berlev
    V. V. Zabrodskii
    S. V. Zadorozhnyi
    A. V. Nikolaev
    N. A. Titov
    E. V. Sherstnev
    Technical Physics, 2020, 65 : 666 - 671
  • [10] NOVEL DETECTOR FOR LOW-ENERGY (3-20 KEV) ELECTRONS
    YANG, T
    KACHNOWSKI, T
    BENCZERKOLLER, N
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (04): : 596 - 596