Peroxyoxalate Chemiluminescence Determination of Polyamines Using On-Line Combination of High-Performance Liquid Chromatography and an Immobilized Enzyme Column Reactor

被引:0
|
作者
School of Pharmaceutical Sciences, Nagasaki University, Bunkyo-machi, Nagasaki 852, Japan [1 ]
机构
来源
Anal. Sci. | / 5卷 / 807-810期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Peroxyoxalate chemiluminescence determination of polyamines using on-line combination of high-performance liquid chromatography and an immobilized enzyme column reactor
    Wada, M
    Kuroda, N
    Ikenaga, T
    Akiyama, S
    Nakashima, K
    ANALYTICAL SCIENCES, 1996, 12 (05) : 807 - 810
  • [2] Determination of aromatic compounds by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection
    Ihara, Ayuko
    Kishikawa, Naoya
    Wada, Mitsuhiro
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    LUMINESCENCE, 2007, 22 (06) : 567 - 574
  • [3] Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection
    Ahmed, Sameh
    Fujii, Shuu
    Kishikawa, Naoya
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) : 76 - 82
  • [4] Determination of vitamin K homologues by high-performance liquid chromatography with on-line photoreactor and peroxyoxalate chemiluminescence detection
    Ahmed, Sameh
    Kishikawa, Naoya
    Nakashima, Kenichiro
    Kuroda, Naotaka
    ANALYTICA CHIMICA ACTA, 2007, 591 (02) : 148 - 154
  • [5] ELECTROCHEMICAL DETECTION OF POLYAMINES USING IMMOBILIZED ENZYME AS POST-COLUMN REACTOR IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WATANABE, N
    ASANO, M
    YAMAMOTO, K
    NAGATSU, T
    MATSUMOTO, T
    FUJITA, K
    CHEMISTRY LETTERS, 1988, (07) : 1169 - 1170
  • [6] Determination of artemisinin in human serum by high-performance liquid chromatography with on-line UV irradiation and peroxyoxalate chemiluminescence detection
    Amponsaa-Karikari, Abena
    Kishikawa, Naoya
    Ohba, Yoshihito
    Nakashima, Kenichiro
    Kuroda, Naotaka
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (11) : 1157 - 1162
  • [7] Application of immobilized enzyme reactor in on-line high performance liquid chromatography: A review
    Girelli, AM
    Mattei, E
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 3 - 16
  • [8] Determination of polyamines by high-performance liquid chromatography with chemiluminescence detection
    Wu, Qiuhua
    Su, Yuqin
    Yang, Lihua
    Li, Jingci
    Ma, Jingjun
    Wang, Chun
    Li, Zhengping
    MICROCHIMICA ACTA, 2007, 159 (3-4) : 319 - 324
  • [9] Determination of polyamines by high-performance liquid chromatography with chemiluminescence detection
    Qiuhua Wu
    Yuqin Su
    Lihua Yang
    Jingci Li
    Jingjun Ma
    Chun Wang
    Zhengping Li
    Microchimica Acta, 2007, 159 : 319 - 324
  • [10] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF BIOLOGICAL POLYAMINES USING IMMOBILIZED ENZYME AS POST-COLUMN REACTOR FOLLOWED BY ELECTROCHEMICAL DETECTION
    WATANABE, N
    ASANO, M
    YAMAMOTO, K
    NAGATSU, T
    MATSUMOTO, T
    FUJITA, K
    BIOMEDICAL CHROMATOGRAPHY, 1989, 3 (05) : 187 - 191