Solar pond operated R134a based vapour absorption heat transformer for process heat generation

被引:0
|
作者
Murugesan, S.N.
Saravanan, R.
Renganarayanan, S.
Mohamed, K.P.
机构
[1] Department of Mechanical Engineering, Cresent Engineering College, Vandalur, Chennai 600 048, India
[2] Institute for Energy Studies, Anna University, Chennai 600 025, India
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Solar ponds provide an inexpensive means for the collection and storage of heat between 50°C and 80°C. They can be utilised efficiently for process heat generation if a suitable vapour absorption heat transformer is used to upgrade the heat. In this paper, a thermodynamic analysis of a vapour absorption heat transformer is presented. This uses R134a (1,1,1,2 - tetrafluroethane) as refrigerant and organic fluids DMAC (Dimethyl acetamide) and DMETEG (Dimethylether tetraethyleneglycol) as absorbents. Variations in performance parameters (coefficient of performance (COP), circulation ratio, second law efficiency) with the following operating parameters have been studied: [Closed Circle] Absorber, generator, evaporator and condenser temperatures. [Closed Circle] Effectiveness of the heat exchangers. The results show that, for high temperature lift, R134a-DMAC has superior performance compared to R134a-DMETEG.
引用
下载
收藏
页码:155 / 162
相关论文
共 50 条
  • [1] R134a and various mixtures of R22/R134a as an alternative to R22 in vapour compression heat pumps
    Karagoz, S
    Yilmaz, M
    Comakli, O
    Ozyurt, O
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (02) : 181 - 196
  • [2] Heat and mass transfer studies on compact generator of R134a/DMF vapour absorption refrigeration system
    Balamurugan, P.
    Mani, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (03): : 506 - 517
  • [3] PERFORMANCE EVALUATION OF R134a/DMF BASED VAPOUR ABSORPTION REFRIGERATION SYSTEM
    Mariappan, Suresh
    Annamalai, Mani
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON INNOVATIVE MATERIALS FOR PROCESSES IN ENERGY SYSTEMS 2010 (IMPRES2010): FOR FUEL CELLS, HEAT PUMPS AND SORPTION SYSTEMS, 2010, : 343 - 349
  • [4] Different methods for modeling absorption heat transformer powered by solar pond
    Sencan, Arzu
    Kizilkan, Onder
    Bezir, Nalan C.
    Kalogirou, Soteris A.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (03) : 724 - 735
  • [5] Heat and mass transfer studies on R134a bubble absorber in R134a/DMF solution based on phenomenological theory
    Suresh, M.
    Mani, A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (13-14) : 2813 - 2825
  • [6] FLOW BOILING HEAT TRANSFER OF R134a IN A MICROCHANNEL HEAT SINK
    do Nascimento, Francisco J.
    Leao, Hugo L. S. L.
    Ribatski, Gherhardt
    PROCEEDINGS OF THE ASME 10TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS 2012, 2012, : 29 - 38
  • [7] Evaluation of a heat transformer powered by a solar pond
    Rivera, W
    Romero, RJ
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2000, 63 (04) : 413 - 422
  • [8] Heat and mass transfer characteristics of absorption of R134a into DMAC in a horizontal tube absorber
    L. Harikrishnan
    M. P. Maiya
    S. Tiwari
    A. Wohlfeil
    F. Ziegler
    Heat and Mass Transfer, 2009, 45 : 1483 - 1491
  • [9] ABSORPTION SYSTEM BASED ON THE REFRIGERANT R134A
    BORDE, I
    JELINEK, M
    DALTROPHE, NC
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (06): : 387 - 394
  • [10] Heat and mass transfer characteristics of absorption of R134a into DMAC in a horizontal tube absorber
    Harikrishnan, L.
    Maiya, M. P.
    Tiwari, S.
    Wohlfeil, A.
    Ziegler, F.
    HEAT AND MASS TRANSFER, 2009, 45 (12) : 1483 - 1491