UHV-compatible fixed-exit two-crystal monochromator

被引:0
|
作者
Kirkland, J.P. [1 ]
Elam, W.T. [1 ]
机构
[1] SFA Inc, Landover, United States
来源
Review of Scientific Instruments | 1995年 / 66卷 / 2 pt 2期
关键词
Alignment - Bearings (machine parts) - Cooling systems - Crystals - Optical design - Semiconducting silicon - Vacuum applications;
D O I
暂无
中图分类号
学科分类号
摘要
The principal objective for the monochromator is to be fixed exit. In addition the design is kept simple, practical and inexpensive. The monochromator design is based on the Cowan boomerang linkage. It has the ability to accept 18 mrad at a distance 12 m from the bending magnet. The crystals are at least 220 mm wide. The water cooling for the first crystal and the bending mechanism for the second have considerable weight. This design supports the crystals on either ends, thus the bearings can be much smaller. Due to the small size of the bearings, the monochromator infrastructure takes up less space. Ultra-high-vacuum compatibility is also one main concern. Though the monochromator will likely operate most of the time with Si(111) crystals, working with other crystals, other 24 spacings, and different energy ranges is being anticipated.
引用
下载
收藏
页码:2135 / 2137
相关论文
共 31 条
  • [1] A UHV-COMPATIBLE FIXED-EXIT 2/4 CRYSTAL MONOCHROMATOR
    KIRKLAND, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 185 - 191
  • [2] AN UHV-COMPATIBLE FIXED-EXIT 2-CRYSTAL MONOCHROMATOR
    KIRKLAND, JP
    ELAM, WT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2135 - 2137
  • [3] Compact fixed-exit UHV DCM for XAFS
    Rickers, K.
    Brueggmann, U.
    Drube, W.
    Herrmann, M.
    Heuer, J.
    Welter, E.
    Schulte-Schrepping, H.
    Schulz-Ritter, H.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 907 - +
  • [4] A SEPARATED CRYSTAL, FIXED-EXIT MONOCHROMATOR FOR X-RAY SYNCHROTRON RADIATION
    MILLS, DM
    KING, MT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3): : 341 - 347
  • [5] One-movement fixed-exit channelcut monochromator
    Oestreich, S
    Kaulich, B
    Barrett, R
    Susini, J
    CRYSTAL AND MULTILAYER OPTICS, 1998, 3448 : 176 - 187
  • [6] Neutron two-crystal monochromator
    Mikerov, V.I.
    Vedernikov, V.I.
    Soldatova, E.N.
    Tukarev, V.A.
    Pribory i Tekhnika Eksperimenta, 1996, (01): : 25 - 29
  • [7] FIXED-EXIT DOUBLE-CRYSTAL MONOCHROMATOR FOR THE DIFFRACTION BEAMLINE AT ELETTRA - A NEW CONCEPT FOR CRYSTAL MOVEMENTS
    BERNSTORFF, S
    BUSETTO, E
    SAVOIA, A
    COLAPIETRO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2065 - 2068
  • [8] Initial characterization and design of an UHV-compatible artificial channel-cut monochromator
    Narayanan, S.
    Sandy, A. R.
    Sprung, M.
    Sullivan, J.
    Preissner, C.
    Shu, D.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 911 - +
  • [9] Fixed-exit double-crystal monochromator for the diffraction beamline at ELETTRA: a new concept for crystal movements
    Bernstorff, S.
    Busetto, E.
    Savoia, A.
    Colapietro, M.
    Review of Scientific Instruments, 1995, 66 (2 pt 2): : 2065 - 2068
  • [10] HARMONIC-FREE AND FIXED-EXIT MONOLITHIC X-RAY MONOCHROMATOR
    HRDY, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1990, 40 (04) : 361 - 366