Automated sample preparation for the determination of budesonide in plasma samples by liquid chromatography and tandem mass spectrometry

被引:0
|
作者
机构
来源
J Chromatogr | / 1-2卷 / 401-409期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An automated bioanalytical method for the determination of the glucocorticosteroid drug budesonide in plasma samples at pM levels was investigated. The method was built using three separate automated analytical steps with manual transfer of samples between them. In the first step, a Tecan RSP150 (Genesis) pipetting robot was used to transfer 1 ml of centrifuged plasma samples and deuterated budesonide internal standard solutions into tubes and to homogenize the resulting admixture. In the second step, a solid-phase extraction was performed using an ASPEC Xli (Gilson) with 100 mg Isolute C18 columns. In order to avoid conventional time-consuming evaporation and reconstitution steps, the solid-phase extraction was coupled on-line to a trace enrichment system for further purification and concentration of the sample extracts. The concentrated samples were eluted in 300 μl ethanol into injection vials, which were capped and transferred to the autosampler in the detection system. In the third step, the pre-treated samples were chromatographed in a gradient LC system and detected using a tandem MS system (Finnigan TSQ 7000), with an atmospheric pressure chemical ionization interface. The described Analytical System consisting of one Tecan robot, two ASPEC systems and one LC-MS-MS system may analyse up to about 800 samples a week with less routine work for the analyst. The concentration range studied was 15 to 2500 pM in 1 ml spiked plasma samples and the limit of quantitation for the described method was determined as 15 pM, as defined by accuracy and precision better than 20%.
引用
收藏
相关论文
共 50 条
  • [1] Automated sample preparation for the determination of budesonide in plasma samples by liquid chromatography and tandem mass spectrometry
    Kronkvist, K
    Gustavsson, M
    Wendel, AK
    Jaegfeldt, H
    JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) : 401 - 409
  • [2] Fully automated sample preparation procedure to measure drugs of abuse in plasma by liquid chromatography tandem mass spectrometry
    Robin, Tiphaine
    Barnes, Alan
    Dulaurent, Sylvain
    Loftus, Neil
    Baumgarten, Sigrid
    Moreau, Stephane
    Marquet, Pierre
    El Balkhi, Souleiman
    Saint-Marcoux, Franck
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (20) : 5071 - 5083
  • [3] Fully automated sample preparation procedure to measure drugs of abuse in plasma by liquid chromatography tandem mass spectrometry
    Tiphaine Robin
    Alan Barnes
    Sylvain Dulaurent
    Neil Loftus
    Sigrid Baumgarten
    Stéphane Moreau
    Pierre Marquet
    Souleiman El Balkhi
    Franck Saint-Marcoux
    Analytical and Bioanalytical Chemistry, 2018, 410 : 5071 - 5083
  • [4] Development and validation of a liquid chromatography and tandem mass spectrometry method for determination of roscovitine in plasma and urine samples utilizing on-line sample preparation
    Vita, M
    Skansen, P
    Hassan, M
    Abdel-Rehim, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 303 - 307
  • [5] Determination of procyanidins and their metabolites in plasma samples by improved liquid chromatography-tandem mass spectrometry
    Serra, Aida
    Macia, Alba
    Romero, Maria-Paz
    Salvado, Maria-Josepa
    Bustos, Mario
    Fernandez-Larrea, Juan
    Motilva, Maria-Jose
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (11-12): : 1169 - 1176
  • [6] Determination of celecoxib in human plasma and rat microdialysis samples by liquid chromatography tandem mass spectrometry
    Bräutigam, L
    Vetter, G
    Tegeder, I
    Heinkele, G
    Geisslinger, G
    JOURNAL OF CHROMATOGRAPHY B, 2001, 761 (02): : 203 - 212
  • [7] Liquid chromatography tandem mass spectrometry determination of total budesonide levels in dog plasma after inhalation exposure
    Seija Berg
    Marika Melamies
    Minna Rajamäki
    Outi Vainio
    Kimmo Peltonen
    Analytical and Bioanalytical Chemistry, 2012, 402 : 1209 - 1215
  • [8] Liquid chromatography tandem mass spectrometry determination of total budesonide levels in dog plasma after inhalation exposure
    Berg, Seija
    Melamies, Marika
    Rajamaki, Minna
    Vainio, Outi
    Peltonen, Kimmo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) : 1209 - 1215
  • [9] Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry
    Vogeser, Michael
    Spohrer, Ute
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (09) : 1126 - 1130
  • [10] Determination of aflatoxins in hazelnuts by various sample preparation methods and liquid chromatography-tandem mass spectrometry
    Bacaloni, Alessandro
    Cavaliere, Chiara
    Cucci, Francesca
    Foglia, Patrizia
    Samperi, Roberto
    Lagana, Aldo
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (02) : 182 - 189