Microdosimetric spectra of α particles measured by a cylindrical flowing tissue equivalent proportional counter

被引:0
|
作者
Zhu, Lianfang
Li, Xuekuan
Chen, Xuebing
He, Yusheng
Zhu, Shaofei
Su, Youwu
Jiao, Dunpang
机构
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:528 / 533
相关论文
共 50 条
  • [1] Microdosimetric measurements at FiR 1 using tissue equivalent proportional counter
    Uusi-Simola, J
    Seppälä, T
    Kosunen, A
    Savolainen, S
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 379 - 381
  • [2] A practical design of a cylindrical tissue-equivalent proportional counter for microdosimetry
    Martin, G
    Gerdung, S
    Raabe, M
    Arend, E
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 379 - 380
  • [3] Modelling and calculations of the response of tissue equivalent proportional counter to charged particles
    Nikjoo, H.
    Uehara, S.
    Pinsky, L.
    Cucinotta, Francis A.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 512 - 518
  • [4] Performance of a cylindrical tissue-equivalent proportional counter for use in neutron monitoring
    Chau, Q
    Lahaye, T
    Ménard, S
    Donadille, L
    Bolognese, T
    Rannou, A
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 297 - 300
  • [5] Microdosimetric Measurements in Gamma and neutron Fields with a Tissue Equivalent Proportional Counter Based on a Gas Electron Multiplier
    De Nardo, L.
    Dal Corso, F.
    Pegoraro, M.
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (02) : 260 - 266
  • [6] Measurement of microdosimetric spectra with a wall-less tissue-equivalent proportional counter for a 290 MeV/u 12C beam
    Tsuda, Shuichi
    Sato, Tatsuhiko
    Takahashi, Fumiaki
    Satoh, Daiki
    Endo, Akira
    Sasaki, Shinichi
    Namito, Yoshihito
    Iwase, Hiroshi
    Ban, Shuichi
    Takada, Masashi
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17): : 5089 - 5101
  • [7] MEASUREMENT OF LET SPECTRA USING A SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER
    WILSON, KSJ
    FIELD, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (04): : 657 - &
  • [8] Geant4 Monte Carlo simulations of a microdosimetric Tissue Equivalent Proportional Counter for carbon ion therapy
    Galer, S.
    Shipley, D.
    Hao, L.
    Palmans, H.
    Kirkby, K.
    Nisbet, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S59 - S60
  • [9] First microdosimetric measurements with a tissue-equivalent proportional counter at the MedAustron ion-beam therapy facility
    Barna, Sandra
    Meouchi, Cynthia
    Magrin, Giulio
    Bianchi, Anna
    Conte, Valeria
    Selva, Anna
    Stock, Markus
    Resch, Andreas Franz
    Georg, Dietmar
    Palmans, Hugo
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1973 - 1978
  • [10] Response of a tissue equivalent proportional counter to neutrons
    Badhwar, GD
    Robbins, DE
    Gibbons, F
    Braby, LA
    RADIATION MEASUREMENTS, 2002, 35 (06) : 551 - 556