Design of a depth of interaction detector with a PS-PMT for PET

被引:0
|
作者
Murayama, H. [1 ]
Ishibashi, H. [1 ]
Uchida, H. [1 ]
Omura, T. [1 ]
Yamashita, T. [1 ]
机构
[1] Natl Inst of Radiological Sciences, Chiba, Japan
关键词
D O I
暂无
中图分类号
学科分类号
摘要
23
引用
收藏
页码:1045 / 1050
相关论文
共 50 条
  • [1] Design of a depth of interaction detector with a PS-PMT for PET
    Murayama, H
    Ishibashi, H
    Uchida, H
    Omura, T
    Yamashita, T
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1062 - 1066
  • [2] Design of a depth of interaction detector with a PS-PMT for PET
    Murayama, H
    Ishibashi, H
    Uchida, H
    Omura, T
    Yamashita, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1045 - 1050
  • [3] Count rate analysis of PET scanner designs based on a GSO depth of interaction detector with a large area PS-PMT
    Kitamura, K
    Amano, M
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1208 - 1212
  • [4] Count rate analysis of PET scanner designs based on a GSO depth of interaction detector with a large-area PS-PMT
    Kitamura, K
    Amano, MR
    Murayama, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2218 - 2222
  • [5] Performance of a PET detector with a 256ch flat panel PS-PMT
    Inadama, N
    Murayama, H
    Watanabe, M
    Omura, T
    Yamashita, T
    Kawai, H
    Umehara, T
    Kasahara, T
    Orita, N
    Tsuda, T
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 939 - 943
  • [6] Performance of a PET detector with a 256ch flat panel PS-PMT
    Inadama, N
    Murayama, H
    Watanabe, M
    Omura, T
    Yamashita, T
    Kawai, H
    Umehara, T
    Kasahara, T
    Orita, N
    Tsuda, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 58 - 62
  • [7] Performance of 256ch flat panel PS-PMT with small crystals for a DOI PET detector
    Inadama, N
    Murayama, H
    Watanabe, M
    Omura, T
    Yamashita, T
    Kawai, H
    Orita, N
    Tsuda, T
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2486 - 2490
  • [8] Performance of 256ch flat panel PS-PMT with small crystals for a DOI PET detector
    Inadama, N
    Murayama, H
    Watanabe, M
    Omura, T
    Yamashita, T
    Kawai, H
    Orita, N
    Tsuda, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 15 - 20
  • [9] A high resolution animal PET scanner using compact PS-PMT detectors
    Watanabe, M
    Okada, H
    Shimizu, K
    Omura, T
    Yoshikawa, E
    Kosugi, T
    Mori, S
    Yamashita, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1277 - 1282
  • [10] A high resolution animal PET scanner using compact PS-PMT detectors
    Watanabe, M
    Okada, H
    Shimizu, K
    Omura, T
    Yoshikawa, E
    Kosugi, T
    Mori, S
    Yamashita, T
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1330 - 1334