MULTIPLE-INPUT CIRCUIT FOR SHAPING PULSES FROM NUCLEAR RADIATION DETECTORS.

被引:0
|
作者
Leshchenko, B.E.
Starichkai, T.
机构
来源
关键词
D O I
暂无
中图分类号
TN7 [基本电子电路];
学科分类号
080902 ;
摘要
A circuit is described that converts signals from nuclear-radiation detectors to logic ones. Voltage comparators are used and also microcircuit univibrators. The length of the length of the output TTL pulse of either polarity can be varied from 40 to 150 nsec. The delay in the output pulse can be varied from 85 nsec upwards by means of RC circuits.
引用
收藏
页码:1205 / 1206
相关论文
共 50 条
  • [1] A MULTIPLE-INPUT CIRCUIT FOR SHAPING PULSES FROM NUCLEAR RADIATION DETECTORS
    LESHCHENKO, BE
    STARICHKAI, T
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (05) : 1205 - 1206
  • [2] SPECTROMETRIC PROPERTIES OF CdTe NUCLEAR RADIATION DETECTORS.
    Kalugina, L.I.
    Pavlova, G.S.
    Mitin, V.I.
    Rodionov, Yu.F.
    Kireev, I.S.
    Vanyukov, A.V.
    1600, (05):
  • [3] Extension of the sensitivity range of nuclear radiation detectors.
    Baumler, E
    Sarkadi, A
    Erdos, K
    Solymosi, J
    Gujgiczer, A
    Illes, Z
    Simoncsics, L
    Plachtovics, G
    MAGYAR KEMIAI FOLYOIRAT, 1997, 103 (09): : 462 - 469
  • [4] A MULTIPLE-INPUT OTA CIRCUIT FOR NEURAL NETWORKS
    REED, RD
    GEIGER, RL
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1989, 36 (05): : 767 - 770
  • [5] Multiple-input OTA circuit for neural networks
    Reed, Russel D.
    Geiger, Randall L.
    IEEE transactions on circuits and systems, 1992, v (0n): : 767 - 770
  • [6] INTRINSIC RESOLVING TIME OF DIAMOND NUCLEAR-RADIATION DETECTORS.
    Kozlov, S.F.
    Likhosherstov, V.N.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1973, 16 (5 Part 1): : 1363 - 1364
  • [7] Shaping pulses of radiation detectors into a true Gaussian form
    Kantor, M. Yu.
    Sidorov, A. V.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (01):
  • [8] The multiple-input translinear element: A versatile circuit element
    Minch, BA
    Hasler, P
    Diorio, C
    ISCAS '98 - PROCEEDINGS OF THE 1998 INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-6, 1998, : 527 - 530
  • [9] MULTICHANNEL RECORDING OF PULSES FROM SEVERAL NUCLEAR RADIATION DETECTORS
    BLYUMKIN.YA
    KAMAEVA, LA
    RODIONOV, NI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (04): : 840 - &
  • [10] CURRENT-MODE MULTIPLE-INPUT MAX CIRCUIT
    BATURONE, I
    HUERTAS, JL
    BARRIGA, A
    SANCHEZSOLANO, S
    ELECTRONICS LETTERS, 1994, 30 (09) : 678 - 680