Experimental study on the critical heat flux at the operating limit of a closed two-phase thermosyphon

被引:0
|
作者
Fukano, Tohru [1 ]
Kadoguchi, Katsuhiko [1 ]
Tien, Chang-Lin [1 ]
机构
[1] Kyushu Univ
来源
Heat Transfer - Japanese Research | 1988年 / 17卷 / 05期
关键词
Evaporators - Heat Transfer--Boiling Liquids;
D O I
暂无
中图分类号
学科分类号
摘要
Flow patterns inside a closed two-phase vertical thermosyphon were visually observed in detail and the relation between the patterns and the operating limit was experimentally investigated. The parameters were the inner diameter of the thermosyphon, the properties and the fill charge of the working fluid and the system pressure. The observations showed that there were two opposite effects of liquid pool boiling in the evaporator on the operating limit due to flooding: a mild boiling delays the dryout of the evaporator wall and a violent one promotes it. Taking these effects into consideration, a correlation was proposed for the large amount of critical heat flux data obtained from many kinds of thermosyphons by using new parameters such as the height of the liquid pool and the bubble kinetic energy. The agreement of the correlation with those data is better than that of Sakhuja's, Prenger's and Imura's correlations.
引用
收藏
页码:43 / 60
相关论文
共 50 条
  • [1] Experimental study on the operating limit of a closed two-phase thermosyphon with a binary mixture
    Kadoguchi, Katsuhiko
    Fukano, Tohru
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1994, 60 (571): : 953 - 959
  • [2] Critical heat flux of a two-phase closed thermosyphon with fins
    Pinate, Wasan
    Rittidech, Sampan
    Meena, Pattanapol
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2018, 32 (05) : 2357 - 2364
  • [3] Critical heat flux of a two-phase closed thermosyphon with fins
    Wasan Pinate
    Sampan Rittidech
    Pattanapol meena
    Journal of Mechanical Science and Technology, 2018, 32 : 2357 - 2364
  • [4] Experimental study of critical heat flux in open two-phase thermosyphon
    Monde, M.
    Mihara, S.
    Mitsutake, Y.
    Heat and Mass Transfer/Waerme- und Stoffuebertragung, 1996, 31 (06): : 393 - 398
  • [5] Experimental study of critical heat flux in open two-phase thermosyphon
    Monde, M
    Mihara, S
    Mitsutake, Y
    HEAT AND MASS TRANSFER, 1996, 31 (06): : 393 - 398
  • [7] Numerical Investigation of the Two-Phase Closed Thermosyphon Operating with Non-Uniform Heat Flux Profiles
    Wang, Zhao
    Turan, Ali
    Craft, Timothy
    ENERGIES, 2023, 16 (13)
  • [8] EXPERIMENTAL STUDY ON HEAT TRANSFER CHARACTERISTICS OF A MODIFIED TWO-PHASE CLOSED THERMOSYPHON
    Aghel, Babak
    Rahmi, Masoud
    Almasi, Saeed
    THERMAL SCIENCE, 2017, 21 (06): : 2481 - 2489
  • [9] Study of heat transfer correlation of two-phase closed thermosyphon
    任丽青
    陈白欣
    刘纪福
    大连理工大学学报, 1999, (04) : 70 - 75
  • [10] Corresponding states correlation for maximum heat flux in two-phase closed thermosyphon
    Golobic, I
    Gaspersic, B
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (06): : 402 - 410