Once-through supercritical boilers are designed to work in starting modes with a feedwater flowrate of 30% of rated. Starting modes are currently being developed for 300 MW power generating units which have boilers equipped with pumps for recirculating the medium. No data are available on starting modes with a feedwater flowrate of less than 30% of rated for power generating units in which the boilers do not have pumps for recirculating the medium or other systems for circulating the medium in the radiant heating surfaces of the boiler during startup. Tests were carried out on a 300 MW power generating unit with a TGMP-114 boiler to determine the feasibility of starting up power generating units with reduced feedwater flows.
引用
收藏
页码:270 / 273
相关论文
共 20 条
  • [1] INVESTIGATING THE STARTING MODES OF A 300-MW POWER GENERATING-UNIT WITH A TGMP-114 BOILER AND RATED FEEDWATER FLOW-RATE REDUCED TO 20-PERCENT
    PROKOPENKO, AG
    MYSAK, IS
    LEONKOV, AM
    KUSKOV, IA
    GERASIMOV, VV
    ZANKOVICH, VL
    ZHADZILKO, MI
    MIRON, DT
    THERMAL ENGINEERING, 1988, 35 (05) : 270 - 273
  • [2] INTRODUCTION OF OIL COMBUSTION IN TGMP-114 BOILER OF A 300 MW UNIT
    GRISHIN, AD
    KAPELSON, LM
    KRUGLOV, BI
    PANCHENK.VF
    THERMAL ENGINEERING, 1972, 19 (02) : 26 - 29
  • [3] Extending the load range of the TGMP-114 boiler and 300 MW generating unit under conditions of variable-pressure operation
    Mysak, I.S.
    Kuskov, I.A.
    Botvinov, V.P.
    Gerasimov, V.V.
    Zankovich, V.L.
    Zhadzilko, M.I.
    Miron, D.T.
    Sytnikova, N.M.
    Thermal Engineering (English translation of Teploenergetika), 1988, 35 (06): : 321 - 326
  • [4] EXTENDING THE LOAD RANGE OF THE TGMP-114 BOILER AND 300 MW GENERATING-UNIT UNDER CONDITIONS OF VARIABLE-PRESSURE OPERATION
    MYSAK, IS
    KUSKOV, IA
    BOTVINOV, VP
    GERASIMOV, VV
    ZANKOVICH, VL
    ZHADZILKO, MI
    MIRON, DT
    SYTNIKOVA, NM
    THERMAL ENGINEERING, 1988, 35 (06) : 321 - 326
  • [5] INVESTIGATING THE STARTING PROCEDURES FOR A 250 MW POWER GENERATING-UNIT WITH REDUCED FEEDWATER FLOWRATES
    GLUSKER, BN
    BERSENEV, AP
    LYSAKOVSKII, VE
    NIKITIN, VA
    NOSOV, BN
    THERMAL ENGINEERING, 1983, 30 (12) : 720 - 723
  • [6] Tests of a 300-MW two-boiler single-turbine power unit with a TGMP-114 boiler when starting with a sliding pressure throughout the water-steam circuit
    Glusker, B.N.
    Kalinitchev, V.M.
    Shcheptev, V.A.
    Garnov, G.V.
    Taran, O.E.
    Platov, A.I.
    Thermal Engineering (English translation of Teploenergetika), 1997, 44 (12):
  • [7] Tests of a 300-MW Two-Boiler Single-Turbine Power Unit with a TGMP-114 Boiler when Starting with a Sliding Pressure Throughout the Water-Steam Circuit
    Entpr. Pwr. Stn. Maintenance, Kostromskya District Power Station, Semenovskii per. 15, Moscow 105023, Russia
    Therm Eng, 12 (1028-1033):
  • [8] MODERNIZING THE POWER-CONTROL SYSTEM IN A 300 MW POWER-GENERATING UNIT WITH A TGMP-324 BOILER
    DUBOV, VN
    BURLAKOV, AV
    MELAMED, AD
    ZISKAND, GA
    THERMAL ENGINEERING, 1989, 36 (10) : 550 - 553
  • [9] Investigating the starting modes of the 300-MW power unit at the Kashira district power station at sliding pressure in the entire steam-water path of its TGMP-314 boiler
    Shvarts A.L.
    Gombolevskii V.I.
    Chugreev A.A.
    Skuratov A.V.
    Konovalov V.K.
    Yashkin O.V.
    Therm Eng, 2008, 9 (719-724): : 719 - 724
  • [10] Study of feedwater regenerative heating operating modes at reduced loads of a turbogenerator by 300 MW power unit capacity
    Limar, Aleksandr
    Babushkin, Aleksey
    Kinash, Ludmila
    Malykov, Aleksey
    Naginaev, Kirill
    INTERNATIONAL CONFERENCE ON MODERN TRENDS IN MANUFACTURING TECHNOLOGIES AND EQUIPMENT (ICMTMTE) 2020, 2020, 971