Background-subtraction of fast-scan cyclic staircase voltammetry at protein-modified carbon-fiber electrodes

被引:0
|
作者
Hayes, Mark A. [1 ]
Kristensen, Eric W. [2 ]
Kuhr, Werner G. [3 ]
机构
[1] Dept. of Chemistry and Biochemistry, Arizona State University, Tempe, AZ 85287-1604, United States
[2] Abbott Labs, Chicago, IL, United States
[3] Dept. of Chem. Univ. of California, Riverside, CA, United States
来源
Biosensors and Bioelectronics | 1998年 / 13卷 / 12期
关键词
Number:; CHE; 8957394; Acronym:; NSF; Sponsor: National Science Foundation; GM44112-01A1; NIH; Sponsor: National Institutes of Health; F32NS009729; NINDS; Sponsor: National Institute of Neurological Disorders and Stroke;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1297 / 1305
相关论文
共 50 条
  • [1] Background-subtraction of fast-scan cyclic staircase voltammetry at protein-modified carbon-fiber electrodes
    Hayes, MA
    Kristensen, EW
    Kuhr, WG
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (12): : 1297 - 1305
  • [2] FAST-SCAN VOLTAMMETRY USING A CARBON-FIBER ULTRAMICRODISK ELECTRODE
    NOMURA, S
    NOZAKI, K
    OKAZAKI, S
    BUNSEKI KAGAKU, 1994, 43 (09) : 719 - 722
  • [3] Wireless transmission of fast-scan cyclic voltammetry at a carbon-fiber microelectrode: proof of principle
    Garris, PA
    Ensman, R
    Poehlman, J
    Alexander, A
    Langley, PE
    Sandberg, SG
    Greco, PG
    Wightman, RM
    Rebec, GV
    JOURNAL OF NEUROSCIENCE METHODS, 2004, 140 (1-2) : 103 - 115
  • [4] Electrochemical Properties of Different Carbon-Fiber Microelectrodes Using Fast-Scan Cyclic Voltammetry
    Huffman, Megan L.
    Venton, B. Jill
    ELECTROANALYSIS, 2008, 20 (22) : 2422 - 2428
  • [5] Ultrafast Detection of Arsenic Using Carbon-Fiber Microelectrodes and Fast-Scan Cyclic Voltammetry
    Manring, Noel
    Strini, Miriam
    Koifman, Gene
    Xavier, Jonathan
    Smeltz, Jessica L.
    Pathirathna, Pavithra
    MICROMACHINES, 2024, 15 (06)
  • [6] Dopamine detection with fast-scan cyclic voltammetry used with analog background subtraction
    Hermans, Andre
    Keithley, Richard B.
    Kita, Justin M.
    Sombers, Leslie A.
    Wightman, R. Mark
    ANALYTICAL CHEMISTRY, 2008, 80 (11) : 4040 - 4048
  • [7] Metal Nanoparticle Modified Carbon-Fiber Microelectrodes Enhance Adenosine Triphosphate Surface Interactions with Fast-Scan Cyclic Voltammetry
    Li, Yuxin
    Keller, Alexandra L.
    Cryan, Michael T.
    Ross, Ashley E.
    ACS MEASUREMENT SCIENCE AU, 2021, 2 (02): : 96 - 105
  • [8] Plasma-treated carbon-fiber microelectrodes for improved purine detection with fast-scan cyclic voltammetry
    Li, Yuxin
    Ross, Ashley E.
    ANALYST, 2020, 145 (03) : 805 - 815
  • [9] Amine-functionalized carbon-fiber microelectrodes for enhanced ATP detection with fast-scan cyclic voltammetry
    Li, Yuxin
    Weese, Moriah E.
    Cryan, Michael T.
    Ross, Ashley E.
    ANALYTICAL METHODS, 2021, 13 (20) : 2320 - 2330
  • [10] Enzyme-Modified Carbon-Fiber Microelectrode for the Quantification of Dynamic Fluctuations of Nonelectroactive Analytes Using Fast-Scan Cyclic Voltammetry
    Lugo-Morales, Leyda Z.
    Loziuk, Philip L.
    Corder, Amanda K.
    Toups, J. Vincent
    Roberts, James G.
    McCaffrey, Katherine A.
    Sombers, Leslie A.
    ANALYTICAL CHEMISTRY, 2013, 85 (18) : 8780 - 8786