INFLUENCE OF TECHNICAL-OPERATIONAL REQUIREMENTS ON GEOMETRIC DEMENSIONS AND LOADS OF EXPLOSION-PROOF INDUCTION MOTORS.

被引:0
|
作者
Goryagin, V.F.
Skripnik, O.N.
Figotina, M.I.
机构
来源
| 1978年 / 49卷 / 02期
关键词
D O I
暂无
中图分类号
TM3 [电机];
学科分类号
080801 ;
摘要
Laws are obtained, with allowance for technical-operational requirements, to relate the power, geometric dimensions, and electromagnetic loads of explosion-proof electric motors. Their accuracy is determined. Recommendations are given for selecting the initial starting-current multiple for prescribed initial-starting-torque and maximum-torque multiples.
引用
收藏
页码:72 / 75
相关论文
共 7 条