摘要
Background to seismic design aspects of the provisional New Zealand Code of Practice for Masonry Structural Design is given. Emphasis is given to reasons for differences in the provisional code from an earlier draft code. The changes include improved compatibility with the current Loadings Code NZS 4203 and the Concrete Design Code NZS 3101, provisions of simplified rules to ensure adequate ductility capacity, and additional information to provide guidance for ductile design of masonry frames. Some experimental results are presented to provide support for the provisions.
引用
下载
收藏
页码:1 / 20
相关论文
共 50 条
  • [1] The 2021 Australian/New Zealand Standard, AS/NZS 1170.2:2021
    Holmes, John D.
    Flay, Richard G. J.
    Ginger, John D.
    Mason, Matthew
    Rofail, Antonios
    Wood, Graeme S.
    WIND AND STRUCTURES, 2023, 37 (02) : 95 - 104
  • [2] Development of the 2005 Edition of the Australian/New Zealand Standard for Cold-Formed Steel Structures AS/NZS 4600
    Hancock, G. J.
    ADVANCES IN STRUCTURAL ENGINEERING, 2008, 11 (06) : 585 - 597
  • [3] Perspective on the seismic design of precast concrete structures in New Zealand
    Univ of Canterbury, Christchurch, New Zealand
    PCI J, 3 (40-60):
  • [4] A PERSPECTIVE ON THE SEISMIC DESIGN OF PRECAST CONCRETE STRUCTURES IN NEW-ZEALAND
    PARK, R
    PCI JOURNAL, 1995, 40 (03): : 40 - 60
  • [5] Seismic vulnerability scenarios of Unreinforced Masonry churches in New Zealand
    T. Goded
    A. Lewis
    M. Stirling
    Bulletin of Earthquake Engineering, 2018, 16 : 3957 - 3999
  • [6] Seismic vulnerability scenarios of Unreinforced Masonry churches in New Zealand
    Goded, T.
    Lewis, A.
    Stirling, M.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2018, 16 (09) : 3957 - 3999
  • [7] Statistical seismic vulnerability of New Zealand unreinforced masonry churches
    Marotta, A.
    Sorrentino, L.
    Liberatore, D.
    Ingham, J. M.
    STRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS: ANAMNESIS, DIAGNOSIS, THERAPY, CONTROLS, 2016, : 1536 - 1543
  • [8] Seismic design of New Zealand houses
    Thurston, Stuart J.
    Park, Stuart G.
    Bulletin of the New Zealand Society for Earthquake Engineering, 2004, 37 (01): : 1 - 12
  • [9] A comparison of the seismic design requirements in the New Zealand loadings standard with other major design codes
    Fenwick, Richard
    Lau, David
    Davidson, Barry
    Bulletin of the New Zealand Society for Earthquake Engineering, 2002, 35 (03): : 190 - 203
  • [10] CONCRETE MASONRY IN NEW-ZEALAND - RATIONAL STRUCTURAL DESIGN OF REINFORCED MASONRY
    HOLMES, IL
    CONCRETE, 1970, 4 (09): : 358 - &