Water-cooled grate systems at the Schwandorf refuse-fired power plant

被引:0
|
作者
Drexler, J. [1 ]
Krueger, J. [1 ]
机构
[1] Muellkraftwerk Schwandorf, Betriebsgesellschaft mbH, Schwandorf, Germany
来源
VGB PowerTech | 2000年 / 80卷 / 08期
关键词
Calorific value - Ducts - Flue gases - Furnace linings - Nozzles - Oxygen - Power plants - Thermal effects - Water cooling systems - Wear of materials;
D O I
暂无
中图分类号
学科分类号
摘要
Water-cooled grate bars were optimized and tested to be suitable for use in boilers on lines 1 to 4 at the Schwandorf incinerator. The temperature could be raised in the cooling system, as it allowed better heat utilization, when a small part of the heat was transferred from the preheated primary air. The anti-boiling margins could be increased without control devices and excessive cooling water volumes.
引用
收藏
页码:34 / 38
相关论文