Effect of Superheated Steam Temperature Variations on the Computed Life Expiration of Pressure-Loaded Parts.

被引:0
|
作者
Pich, R. [1 ]
机构
[1] Energie- und Verfahrens-technik GmbH, Stuttgart, West Ger, Energie- und Verfahrens-technik GmbH, Stuttgart, West Ger
来源
VGB-Kraftwerkstechnik | 1985年 / 65卷 / 08期
关键词
STEAM GENERATORS - Piping Systems - STRESSES - Thermal;
D O I
暂无
中图分类号
学科分类号
摘要
Normal steam temperature variations can mostly be ignored when considering life expectation due to alternating stresses. The effect on life expiration due to creep is significantly smaller than that due to constant temperature excess and is simple to compensate for by slight temperature increases. The main steam connections between the steam generator and the turbine reduce the superheated steam temperature variations by about half.
引用
收藏
页码:748 / 753