Development of a computerized measurement method on three dimensional alignment of the target center in a stereotactic radiosurgery system

被引:0
|
作者
Shiraishi, J. [1 ]
Yanagihara, Y. [1 ]
Tanaka, K. [1 ]
Hama, H. [1 ]
机构
[1] Department of Radiology, Osaka City University Hospital, 1-5-7 Asahi-machi, Abeno-ku, Osaka 545-8586, Japan
关键词
Phantom images - Stereotactic radiosurgery;
D O I
10.3169/itej.55.133
中图分类号
学科分类号
摘要
引用
收藏
页码:133 / 140
相关论文
共 50 条
  • [1] A three-dimensional computerized isometric strength measurement system
    Black, Nancy L.
    Das, Biman
    APPLIED ERGONOMICS, 2007, 38 (03) : 285 - 292
  • [2] Computerized method for measurement of displacement vectors of target positions on EPID cine images in stereotactic radiotherapy
    Arimura, Hidetaka
    Anai, Shigeo
    Yoshidome, Satoshi
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Nomoto, Satoshi
    Honda, Hiroshi
    Onizuka, Yoshihiko
    Terashima, Hiromi
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [3] Development of a three dimensional space charge measurement system for dielectrics using PWP method
    Tian, Y
    Chen, G
    Davies, AE
    2002 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2002, : 644 - 647
  • [4] Development of a rapid planning technique based on heuristic target shaping for stereotactic radiosurgery
    Oh, S
    Suh, TS
    Song, JY
    Choe, BY
    Lee, HK
    Kim, MC
    Lee, T
    MEDICAL PHYSICS, 2004, 31 (02) : 175 - 182
  • [5] A rapid three-dimensional measurement method for non-cooperative target
    Sun Xiuqing
    Zhang Duzhou
    Wang Li
    Wu Fenzhi
    CHINESE SPACE SCIENCE AND TECHNOLOGY, 2018, 38 (01) : 77 - 83
  • [6] RAPID METHOD FOR DETERMINATION OF ISOCENTER OF RADIATION GANTRY AND ALIGNMENT OF LASER-BEAMS FOR STEREOTACTIC RADIOSURGERY
    HEIFETZ, MD
    ROSEMARK, PJ
    WEXLER, MC
    GREENBERG, SH
    THOMPSON, RW
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1989, 53 (01) : 46 - 48
  • [7] A novel three-dimensional radiochromic film phantom for use with stereotactic radiosurgery units
    Griffin, S.
    DeWerd, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 1991 - 1991
  • [8] Three-Dimensional Gel Dosimetry for Dose Volume Histogram Verification in Stereotactic Radiosurgery
    Semnicka, J.
    Novotny, J., Jr.
    Spevacek, V.
    Garcic, J.
    Steiner, M.
    Judas, L.
    RADIOSURGERY, VOL 7, 2010, 7 : 44 - 55
  • [9] A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery
    Robar, JL
    Clark, BG
    MEDICAL PHYSICS, 2000, 27 (05) : 978 - 987
  • [10] On TMR Measurement of a New Self-Shielded Stereotactic Radiosurgery (SRS) System
    Yan, X.
    Pinnaduwage, D.
    Jani, S.
    Srivastava, S.
    Bodduluri, M.
    Weidlich, G.
    Sorensen, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E554 - E554