Calibration of a PET detector module that measures depth of interaction

被引:0
|
作者
Univ of California, Berkeley, United States [1 ]
机构
来源
IEEE Trans Nucl Sci | / 3 pt 2卷 / 1268-1272期
关键词
Attenuation - Calibration - Computer simulation - Gain measurement - Gamma rays - Optical resolving power - Positron emission tomography - Signal to noise ratio - Spurious signal noise;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Calibration of a PET detector module that measures depth of interaction
    Huber, JS
    Moses, WW
    Virador, PRG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1268 - 1272
  • [2] A depth of interaction PET detector module.
    Miyaoka, RS
    Lewellen, TK
    Yu, H
    McDaniel, DL
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 170P - 170P
  • [3] Design of a depth of interaction (DOI) PET detector module
    Miyaoka, RS
    Lewellen, TK
    Yu, JH
    McDaniel, DL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1069 - 1073
  • [4] Design of a depth of interaction (DOI) PET detector module
    Miyaoka, RS
    Lewellen, TK
    Yu, H
    McDaniel, DL
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 939 - 943
  • [5] Development of a PET detector module with Depth of Interaction capability
    Morrocchi, Matteo
    Ambrosi, Giovanni
    Bisogni, Maria Giuseppina
    Cerello, Piergiorgio
    Corsi, Francesco
    Ionica, Maria
    Marino, Naema
    Marzocca, Cristoforo
    Pennazio, Francesco
    Pirrone, Giovanni
    Santoni, Cristiano
    Wheadon, Richard
    Del Guerra, Alberto
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 603 - 606
  • [6] ROOM-TEMPERATURE LSO PIN PHOTODIODE PET DETECTOR MODULE THAT MEASURES DEPTH OF INTERACTION
    MOSES, WW
    DERENZO, SE
    MELCHER, CL
    MANENTE, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1085 - 1089
  • [7] An LSO scintillator array for a PET detector module with depth of interaction measurement
    Huber, JS
    Moses, WW
    Andreaco, MS
    Petterson, O
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 684 - 688
  • [8] Calibration Methodology for a Dual-ended Readout Silicon Photomultiplier Based Depth-of-interaction PET Detector Module
    Xi, W.
    McKisson, J. E.
    Weisenberger, A. G.
    Lee, S.
    Taylor, M.
    Stepanyan, A.
    Zorn, C.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3493 - 3495
  • [9] A GSO depth of interaction detector for PET
    Yamamoto, S
    Ishibashi, H
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 944 - 948
  • [10] DESIGN STUDIES FOR A PET DETECTOR MODULE USING A PIN PHOTODIODE TO MEASURE DEPTH OF INTERACTION
    MOSES, WW
    DERENZO, SE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1441 - 1445