MAGNETIC SPECTROMETER BASED ON MULTIWIRE PROPORTIONAL CHAMBERS.

被引:0
|
作者
Baranov, A.M. [1 ]
Baskakov, V.I. [1 ]
Bondarenko, G.B. [1 ]
Vasil'ev, P.S. [1 ]
Gavrilenko, I.L. [1 ]
Dolgoshein, B.A. [1 ]
Konovalov, V.P. [1 ]
Konovalov, S.P. [1 ]
Konstantinov, A.M. [1 ]
Murav'ev, S.V. [1 ]
Semenov, V.K. [1 ]
Shmeleva, A.P. [1 ]
机构
[1] Moscow Applied Physics Inst, Moscow, USSR, Moscow Applied Physics Inst, Moscow, USSR
来源
关键词
PROPORTIONAL COUNTERS;
D O I
暂无
中图分类号
学科分类号
摘要
The characteristics of a magnetic spectrometer based on multiwire proportional chambers with cathode data output are investigated. The momentum resolution of the spectrometer is less than equivalent to 1% for particles with momenta of 1-5 Gev/c.
引用
收藏
页码:543 / 545
相关论文
共 50 条
  • [1] MAGNETIC SPECTROMETER BASED ON MULTIWIRE PROPORTIONAL CHAMBERS
    BARANOV, AM
    BASKAKOV, VI
    BONDARENKO, GB
    VASILEV, PS
    GAVRILENKO, IL
    DOLGOSHEIN, BA
    KONOVALOV, VP
    KONOVALOV, SP
    KONSTANTINOV, AM
    MURAVEV, SV
    SEMENOV, VK
    SHMELEVA, AP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1985, 28 (03) : 543 - 545
  • [2] MULTIWIRE PROPORTIONAL CHAMBERS IN A 1 GEV-C MAGNETIC SPECTROMETER
    CHIBA, M
    DAIGO, M
    KATO, S
    KONDO, K
    TOSHIOKA, K
    WATANABE, K
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1976, 15 (06) : 1135 - 1143
  • [3] MEASUREMENTS OF THE TIME RESOLUTION AND RATE CAPABILITY OF MULTIWIRE PROPORTIONAL CHAMBERS.
    Duerdoth, P.
    Ellison, R.J.
    Jones, R.E.H.
    Mercer, D.
    Cake, B.V.
    Clarke, D.
    Nuclear Instruments and Methods, 1975, 120 (02): : 461 - 465
  • [4] SYSTEM OF MULTIWIRE PROPORTIONAL CHAMBERS FOR A LARGE APERTURE SPECTROMETER
    CAVALLISFORZA, M
    GOGGI, G
    PIAZZOLI, A
    ROSSINI, B
    SCANNICCHIO, D
    NUCLEAR INSTRUMENTS & METHODS, 1975, 124 (01): : 73 - 82
  • [5] SHOCK TENSOMETER FOR MULTIWIRE CHAMBERS.
    Zyazyulya, F.E.
    Korenchenko, S.M.
    Smirnov, V.S.
    Instruments and experimental techniques New York, 1986, 29 (1 pt 2): : 163 - 166
  • [6] Multiwire proportional chambers
    Alfaro, R
    Menchaca-Rocha, A
    INSTRUMENTATION IN ELEMENTARY PARTICLE PHYSICS, 2003, 674 : 305 - 312
  • [7] GAIN REDUCTION DUE TO SPACE CHARGE AT HIGH COUNTING RATES IN MULTIWIRE PROPORTIONAL CHAMBERS.
    Smith, G.C.
    Mathieson, E.
    IEEE Transactions on Nuclear Science, 1986, NS-34 (01) : 410 - 413
  • [8] MULTIWIRE PROPORTIONAL CHAMBERS AND DRIFT CHAMBERS
    CHARPAK, G
    SAULI, F
    NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 405 - 428
  • [9] SYSTEM OF PROPORTIONAL CHAMBERS FOR MAGNETIC SPECTROMETER
    AZHGIREI, LS
    AKIMOVA, GF
    BUDKIN, LV
    VZOROV, IK
    ZRELOV, PV
    IGNATENKO, MA
    KOZHEVNIKOV, YA
    KUZNETSOV, AS
    SAMOILOV, VN
    STOLETOV, GD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (04) : 797 - 802
  • [10] SURVEY ON MULTIWIRE PROPORTIONAL CHAMBERS
    VERESS, I
    MONTVAI, A
    NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2): : 73 - 80