An effective stress parameter for long-term fatigue strength of fiber-reinforced plastic pipes

被引:0
|
作者
Kujawski, D. [1 ]
Chiu, A.S. [1 ]
Ellyin, F. [1 ]
机构
[1] Dept of Mechanical Eng, Univ of Alberta, Edmonton Alberta T6G 2G8, Canada
来源
关键词
Fatigue of materials - Fatigue testing - Plastic pipe - Pressure effects - Strength of materials - Stress analysis - Stress concentration;
D O I
暂无
中图分类号
学科分类号
摘要
The currently used American Society for Testing and Materials (ASTM) procedure and a modified American Petroleum Institute (API) method for cyclic pressure strength of fibre reinforced plastic (FRP) pipes are critically discussed together with the test results generated by Battelle. In addition, two new damage parameters, recently proposed by the authors, are examined using the Battelle tests as a database. An equivalent stress range damage parameter, Δσ¯, is recommended which combined the loading condition, hoop stress range and normalized mean stress, and FRP pipe material properties. The proposed damage parameter, Δσ¯, can be used in the engineering evaluation of fatigue performance of pressured fiberglass pipes. The Δσ¯ provides substantial improvement over the ASTM recommended parameter, hoop stress range. Using the Δσ¯, the fatigue data for different mean pressures are consolidated into a narrow scatter band.
引用
收藏
页码:215 / 220
相关论文
共 50 条
  • [1] An effective stress parameter for long-term fatigue strength of fiber-reinforced plastic pipes
    Kujawski, D
    Chiu, ASF
    Ellyin, F
    [J]. JOURNAL OF COMPOSITES TECHNOLOGY & RESEARCH, 1996, 18 (03): : 215 - 220
  • [2] Effect of aqueous environment on the long-term behavior of glass fiber-reinforced plastic pipes
    Farshad, M
    Necola, A
    [J]. POLYMER TESTING, 2004, 23 (02) : 163 - 167
  • [3] FIBER-REINFORCED PLASTIC PIPES AND APPLICATIONS
    AINSWORTH, L
    [J]. COMPOSITES, 1981, 12 (03): : 185 - 190
  • [4] Measurement and prediction for long-term stiffness of glass fiber reinforced plastic pipes
    Zhu S.
    Liang N.
    Li Y.
    Chen J.
    [J]. Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2016, 33 (11): : 2492 - 2499
  • [5] Simulation of the long-term hydrostatic tests on Glass Fiber Reinforced Plastic pipes
    Rafiee, Roham
    Mazhari, Behzad
    [J]. COMPOSITE STRUCTURES, 2016, 136 : 56 - 63
  • [6] A new test method for evaluating the long-term performance of fiber-reinforced concrete pipes
    Al Rikabi, Fouad T.
    Sargand, Shad M.
    Khoury, Issam
    Kurdziel, John
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (07) : 1336 - 1349
  • [7] Evaluating long-term performance of Glass Fiber Reinforced Plastic pipes subjected to internal pressure
    Rafiee, Roham
    Mazhari, Behzad
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 122 : 694 - 701
  • [8] The long-term compressive strength and durability properties of silica fume fiber-reinforced concrete
    Nili, Mahmoud
    Afroughsabet, V.
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2012, 531 : 107 - 111
  • [9] Effects of local fiber discontinuity on the fatigue strength parameter at the fiber inclusion corner in fiber-reinforced composites
    Wang, Cong-Man
    Ping, Xue-Cheng
    Wang, Xing-Xing
    [J]. SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2022, 29 (01) : 274 - 286
  • [10] Physical and water aging of glass fiber-reinforced plastic pipes
    Stocchi, A.
    Pellicano, A.
    Rossi, J. P.
    Bernal, C.
    Montemartini, P.
    [J]. COMPOSITE INTERFACES, 2006, 13 (8-9) : 685 - 697