PREVENT SYSTEM CONTAMINATION WITH HYDRAULIC OIL ANALYSIS.

被引:0
|
作者
Leugner, L.O. [1 ]
机构
[1] Phoenix Maintenance & Service, Management, Edmonton, Alberta, Can, Phoenix Maintenance & Service Management, Edmonton, Alberta, Can
来源
Engineering and contract record | 1985年 / 98卷 / 12期
关键词
HYDRAULIC SYSTEM FAILURES - PARTICLE GENERATION - WEAR LEVELS;
D O I
暂无
中图分类号
学科分类号
摘要
Hydraulics represent a critical point in plant and mobile equipment maintenance. Most hydraulic systems today have the following characteristics with regard to causes of failure: a) Water contamination b) High levels of abrasive contaminant particles c) Excessive external leakage past seals and wipers d) Internal leakage past eroded valves caused by contamination buildup. Most companies use the standard oil analysis method of measuring wear metals to determine the condition of the hydraulic systems on plant and mobile equipment.
引用
收藏
相关论文
共 50 条
  • [1] PREVENT SYSTEM CONTAMINATION WITH HYDRAULIC OIL ANALYSIS
    LEUGNER, LO
    CANADIAN MINING JOURNAL, 1985, 106 (12) : S5 - S6
  • [2] Configuring a system for hydraulic oil contamination management
    Dusa, Petru
    Purice, Eugen
    Lupascu, Radu
    Ripanu, Iustina
    Fandarac, Gabriel
    22ND INTERNATIONAL CONFERENCE ON INNOVATIVE MANUFACTURING ENGINEERING AND ENERGY - IMANE&E 2018, 2018, 178
  • [3] Failure Prevention of Hydraulic System Based on Oil Contamination
    M. Singh
    G. S. Lathkar
    S. K. Basu
    Journal of The Institution of Engineers (India): Series C, 2012, 93 (3) : 269 - 274
  • [4] Reliability optimization design of hydraulic system considering oil contamination
    Zhou, Xinda
    Yang, Zhaojun
    Tian, Hailong
    Chen, Chuanhai
    Wang, Liding
    Zhu, Yongfu
    Liu, Jia
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (12) : 5041 - 5051
  • [5] Reliability optimization design of hydraulic system considering oil contamination
    Xinda Zhou
    Zhaojun Yang
    Hailong Tian
    Chuanhai Chen
    Liding Wang
    Yongfu Zhu
    Jia Liu
    Journal of Mechanical Science and Technology, 2020, 34 : 5041 - 5051
  • [6] Active control of hydraulic oil contamination to extend the service life of aviation hydraulic system
    Ren-cai Zhang
    Xiang Yu
    Yun-long Hu
    Hong-jiao Zang
    Wen Shu
    The International Journal of Advanced Manufacturing Technology, 2018, 96 : 1693 - 1704
  • [7] Active control of hydraulic oil contamination to extend the service life of aviation hydraulic system
    Yu, Xiang (yuxiang@cugb.edu.cn), 1693, Springer London (96): : 5 - 8
  • [8] Active control of hydraulic oil contamination to extend the service life of aviation hydraulic system
    Zhang, Ren-cai
    Yu, Xiang
    Hu, Yun-long
    Zang, Hong-jiao
    Shu, Wen
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2018, 96 (5-8): : 1693 - 1704
  • [9] Prediction of Oil Contamination in Aviation Hydraulic System and Active Leakage Strategy
    Zhang, Yongwei
    Liu, Yongji
    Wang, Zhaoxiong
    Tao, Yuhua
    Yang, Liman
    Li, Yunhua
    2022 IEEE 17TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2022, : 578 - 583
  • [10] Electricity conductance method for hydraulic oil contamination monitoring and experiment analysis
    Tu, QZ
    Gong, LH
    Zuo, HF
    ICEMI'2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1-3, 2003, : 2114 - 2117