Comparison of results between use of precocious and conventional amniocentesis

被引:0
|
作者
Frants, Nilo [1 ]
Maia, Carlos Roberto [1 ]
De Souza, Ana Lucia Semmelmann [1 ]
Frajndlich, Renato [1 ]
机构
[1] Clinica de Ultra-Sonografia, Porto Alegre, Brazil
来源
Ultrasound in Medicine and Biology | 1997年 / 23卷 / Suppl 1期
关键词
Obstetrics;
D O I
暂无
中图分类号
R96 [药理学]; R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ; 100706 ;
摘要
Verify the incidence of failure of culture and loss of fetus resulting from precious amniocentesis (prior to 15 weeks) and conventional amniocentesis (after 15 weeks) and to compare the results obtained with the two procedures. Between 1993 and 1997 precocious amniocentesis was realized in 975 cases and conventional amniocentesis in 918 cases. For this purpose 22 g needle was used with due care to avoid transfixation of placenta, removing approximately 20 ml of amniotic liquid. In the group of precocious amniocentesis failure of culture was observed in 1.553% (n = 15), there was 0.61% (n = 6) of fetal loss, and 2.05% (n = 20) of altered cariotypes. In the conventional amniocentesis group the following values were registered. 1.415 (n = 13) of failure of culture, 0.54% (n = 5) of loss of fetus and 1.74% (n = 16) of altered varitypes. The results of the present study permit to conclude that no increase in the incidence of failure of culture and loss of fetus could be observed when precocious amniocentesis was used considering conventional amniocentesis as reference.
引用
收藏
相关论文
共 50 条
  • [1] PRECOCIOUS AMNIOCENTESIS
    TAILLEMITE, JL
    REVUE DU PRATICIEN, 1981, 31 (44): : 3099 - 3102
  • [2] Comparison between CVS and early amniocentesis
    Tavares, P
    Tavares, A
    Rendeiro, P
    Palmares, C
    PRENATAL DIAGNOSIS, 1998, 18 (01) : 87 - 87
  • [3] Comparison of miscarriage rates between early and late amniocentesis
    Mulvey, S
    Wallace, EM
    PRENATAL DIAGNOSIS, 2000, 20 (03) : 265 - 266
  • [4] DIAGNOSTIC USE OF AMNIOCENTESIS - DIAGNOSTIC USE OF AMNIOCENTESIS - TECHNIQUE AND COMPLICATIONS
    SCRIMGEOUR, JB
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1971, 64 (11): : 1135 - +
  • [5] Comparison of early postoperative results between conventional and transapical mitral valve repair
    Zorinas, Aleksejus
    Lipnevicius, Artaras
    Bleizgyte, Viktorija
    Janusauskas, Vilius
    Liekiene, Daina
    Budra, Mindaugas
    Samalavicius, Robertas Stasys
    Drasutiene, Agne
    Zakarkaite, Diana
    Aidietis, Audrius
    Rucinskas, Kestutis
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2019, 15 (04): : 439 - 445
  • [6] Comparison of early results between endovascular or conventional repair of aortic abdominal aneurysm
    de Lima, AA
    Parodi, JC
    Lamura, R
    Ferreira, M
    Garelli, G
    Cersosimo, H
    Galarza, F
    EUROPEAN HEART JOURNAL, 2000, 21 : 87 - 87
  • [7] COMPARISON OF CVS AND AMNIOCENTESIS
    PERGAMENT, E
    GINSBERG, N
    VERLINSKY, Y
    CLINICAL GENETICS, 1985, 28 (05) : 455 - 456
  • [8] LIBERAL USE OF AMNIOCENTESIS
    不详
    SOUTH AFRICAN MEDICAL JOURNAL, 1978, 54 (27): : 1115 - 1116
  • [9] Comparison Between Some Results Measured with an Urusasa & Hues and the Conventional Sound Level Meters
    Furihata, K.
    Yanagisawa, T.
    Proceedings - International Conference on Noise Control Engineering, (05):
  • [10] Comparison between some results measured with an ''urusasa & hues'' and the conventional sound level meters
    Furihata, K
    Yanagisawa, T
    INTER-NOISE 96 - THE 1996 INTERNATIONAL CONGRESS ON NOISE CONTROL ENGINEERING, 25TH ANNIVERSARY CONGRESS - LIVERPOOL, PROCEEDINGS, BOOKS 1-6: NOISE CONTROL - THE NEXT 25 YEARS, 1996, : 2601 - 2604