VALVE STEM PACKING IMPROVEMENT STUDY.

被引:0
|
作者
ADEY, C.W.
KLEIN, J.J.
机构
来源
| 1982年
关键词
D O I
暂无
中图分类号
学科分类号
摘要
BY EMPLOYING QUESTIONAIRES AND FACE-TO-FACE INTERVIEWS WITHVALVE AND VALVE PACKING MANUFACTURERS, AS WELL AS NUCLEAR PLANT PERSONNEL, AN UNDERSTANDING OF VALVE STEM PACKING LEAKAGE PROBLEMS FROM EACH OF THE THREE VIEWPOINTS WAS DEVELOPED.THIS INFORMATION, IN-HOUSE EXPERIENCE, AND AVAILABLE TECHNICAL LITERATURE WERE USED TO DEVELOP SPECIFIC RECOMMENDATIONSFOR VALVE MANUFACTURERS, VALVE PACKING MANUFACTURERS, AND NUCLEAR PLANT VALVE USERS. IT WAS GENERALLY RECOMMENDED THAT EACH OF THESE GROUPS MAKE BETTER USE OF GRAPHITE PACKING. THE QUESTIONNAIRES AND INTERVIEWS INDICATED THAT INCREASED USAGE OF GRAPHITE PACKING OVER THE LAST FEW YEARS HAS REDUCED THE INCIDENCE OF VALVE PACKING PROBLEMS. TO CONFIRM THIS, A SURVEY OF LICENSEE EVENT REPORTS (LERS) FROM 1972 TO 1980 WASUNDERTAKEN USING THE KEYWORDS ″ VALVE ″ AND ″ PACKING ″ . ASTATISTICAL ANALYSIS OF THE LER DATA CONFIRMS THAT THE ADOPTION OF GRAPHITE PACKING HAS SIGNIFICANTLY REDUCED VALVE STEM LEAKAGE.
引用
收藏
相关论文
共 50 条
  • [1] TEMPERATURE CONTROL OF VALVE STEM PACKING
    CHINN, GI
    INSTRUMENTS & CONTROL SYSTEMS, 1969, 42 (02): : 117 - &
  • [2] Tribological investigation of packing friction along the stem of a valve
    Ho, X. J.
    Saulot, A.
    Busquet, M.
    Berthier, Y.
    Torrance, A. A.
    Hersant, D.
    TRIBOLOGY INTERNATIONAL, 2013, 65 : 354 - 362
  • [3] GRAVEL PACKING SAND QUALITY - A QUANTITATIVE STUDY.
    Zwolle, Simon
    Davies, David R.
    JPT, Journal of Petroleum Technology, 1983, 35 (07): : 1042 - 1050
  • [4] NUCLEAR VALVE STEM PACKING IMPROVEMENTS CAN REDUCE LEAKAGE
    RUGGIERI, SK
    POWER ENGINEERING, 1986, 90 (09) : 26 - 29
  • [5] Predicting Leak Rate Through Valve Stem Packing in Nuclear Applications
    Aweimer, Ali Salah Omar
    Bouzid, Abdel-Hakim
    Kazeminia, Mehdi
    JOURNAL OF NUCLEAR ENGINEERING AND RADIATION SCIENCE, 2019, 5 (01):
  • [6] SYSTEM IMPROVEMENT - REPORT ON A PILOT STUDY.
    Joshi, S.S.
    Manohar, V.N.
    Ranade, S.P.
    Joshi, P.K.
    1600, (24):
  • [7] VAP prevention: A quality improvement study.
    Clarke, F. J.
    Tkaczyk, A. J.
    Kraus, S.
    Lutz, K.
    McDonald, E.
    Zhou, Q.
    Cook, D. J.
    Maclennan, M.
    CRITICAL CARE MEDICINE, 2007, 35 (12) : A267 - A267
  • [8] Percutaneous replacement of the aortic valve: A lamb study.
    Younes, B
    Philipp, B
    CIRCULATION, 2001, 104 (17) : 582 - 582
  • [9] Development of a versatile packing for fugitive emission control, in rising stem and rotary valve
    Jefferies, A
    Edwin-Scott, D
    2ND EUROPEAN FUGITIVE EMISSIONS CONFERENCE, 1998, 1441 : 315 - 328
  • [10] Development of a Versatile Packing for Fugitive Emission Control, in Rising Stem and Rotary Valve
    Jefferies, A.
    Edwin-Scott, D.
    VDI Berichte, 1998, (1441): : 315 - 328