A biolized implantable ventricular assist device compatible with IABP console

被引:0
|
作者
Chen, J.-F. [1 ]
Fujimoto, L.K. [1 ]
Kiraly, R.R. [1 ]
Massiello, A. [1 ]
Uchida, N. [1 ]
Nose, Y. [1 ]
机构
[1] Department of Artificial Organs, The Cleveland Clinic Foundation, Cleveland, OH 44195-5132, United States
来源
ASAIO Transactions | 1989年 / 35卷 / 03期
关键词
Biological materials--Blood - Biomaterials--Biocompatibility - Pumps--Medical Applications;
D O I
10.1097/00002216-198907000-00073
中图分类号
学科分类号
摘要
A low pressure pneumatic pusher plate blood pump was developed for temporary right, left, or biventricular assist. Important features of this pump are its 1) driveability by the standard, easily available intraaortic balloon pump (IABP) console; 2) gelatin coated internal surface for blood compatibility; 3) essentially flat disc shape, 3 cm thick and 11 cm in diameter, for optimal anatomic fit; and 4) unique pusher plate guide mechanism to ensure linear motion without deflections of the diaphragm, and consequent uniform flow distribution into the pump. The guide telescopes into itself to avoid a housing protrusion for easy implantability; this controlled movement also provides a number of performance, control, and diagnostic benefits. No anticoagulation was required.
引用
收藏
页码:398 / 401
相关论文
共 50 条
  • [1] PRECLINICAL EVALUATION OF A BIOLIZED TEMPORARY VENTRICULAR ASSIST DEVICE
    YOZU, R
    GOLDING, LAR
    JACOBS, G
    MURABAYASHI, S
    HARASAKI, H
    KIRALY, RJ
    NOSE, Y
    CLEVELAND CLINIC QUARTERLY, 1984, 51 (01): : 119 - 126
  • [2] BIOLIZED INTRATHORACIC LEFT-VENTRICULAR ASSIST DEVICE (LVAD)
    HAYASHI, K
    SNOW, J
    WASHIZU, T
    JACOBS, GB
    KIRALY, RJ
    NOSE, Y
    MEDICAL INSTRUMENTATION, 1977, 11 (04): : 202 - 207
  • [3] The Review of Extracorporeal Ventricular Assist Device Use Post Approval of Implantable Ventricular Assist Device
    Tatsuki, Fujiwara
    Mizuno, Tomohiro
    Oi, Keiji
    Yashima, Masafumi
    Hachimaru, Tsuyoshi
    Nagaoka, Eiki
    Sasaoka, Taro
    Isobe, Mitsuaki
    Arai, Hirokuni
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : S168 - S168
  • [4] Development of implantable right ventricular assist device
    Furukawa, K
    Motomura, T
    Hata, A
    Asai, T
    Yuri, K
    Iwahashi, H
    Tanaka, A
    Nosé, Y
    ASAIO JOURNAL, 2004, 50 (06) : 543 - 549
  • [5] Totally implantable intrathoracic ventricular assist device
    Mussivand, TV
    Masters, RG
    Hendry, PJ
    Keon, WJ
    ANNALS OF THORACIC SURGERY, 1996, 61 (01): : 444 - 447
  • [6] BIOLIZED INTRA-THORACIC LEFT-VENTRICULAR ASSIST DEVICE FOR CHRONIC HUMAN USE
    MURABAYASHI, S
    SUKALAC, R
    HARASAKI, H
    OZAWA, K
    SUWA, S
    KIRALY, RJ
    NOSE, Y
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 179 (MAR): : 15 - ORPL
  • [7] Right ventricular failure after left ventricular assist device implantation:: The need for an implantable right ventricular assist device
    Furukawa, K
    Motomura, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2005, 29 (05) : 369 - 377
  • [8] Development of Miniature, Implantable Pediatric Ventricular Assist Device
    Wearden, P. D.
    Snyder, T. A.
    Stanfield, J. R.
    Coghill, P.
    Crompton, D.
    Olia, S. E.
    Ye, S.
    Kameneva, M. V.
    Wagner, W. R.
    Long, J. W.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S163 - S163
  • [9] AN IMPLANTABLE LEFT VENTRICULAR-AORTIC ASSIST DEVICE
    FILLER, RM
    BERNHARD, WF
    BANKOLE, M
    LAFARGE, CG
    ROBINSON, T
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1967, 54 (06): : 795 - &
  • [10] Implantable Ventricular Assist Device Use in the Immunosuppressed Patient
    Jones, S.
    Naka, Y.
    Ota, T.
    Khalpey, Z.
    Margolis, L.
    Naroji, S.
    Yerebakan, H.
    Uriel, N.
    Colombo, P.
    Jorde, U.
    Takayama, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S274 - S274