Transpedicular screw-rod fixation in the treatment of unstable lower thoracic and lumbar fractures

被引:0
|
作者
Mozes, G.C. [1 ]
Kollender, Y. [1 ]
Sasson, A.A. [1 ]
机构
[1] Department of Orthopaedic Surgery, Soroka Medical Center, University of Ben Gurion, Beer-Sheva, Israel
关键词
Bone - Musculoskeletal system - Neurology - Orthopedics - Patient monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
A total of 41 consecutive cases of unstable lumbar and lower thoracic spine fractures or fracture dislocations were treated by the authors at the Soroka Medical Center, Beer-Sheva, Israel between 1988 and 1992, using the Dick Internal Fixator, for reduction of the deformity and fixation. Twenty-nine of the 41 cases, 19 males and 10 females with an average age was 30.5 years, had a mean postoperative follow-up of 24 months Their injuries, 44 fractured vertebrae, were due to road traffic accident in 11 instances, falls from a height in 11 (of whom 4 were suicide attempts), work accidents in 6, and gunshot wound in 1. Among the vertebral injuries, 3 patients sustained a two-column injury and 26 a three-column injury, according to the Denis classification. Reduction of the kyphotic deformity was achieved, obtaining the proper height of the injured vertebra or reduction of the fracture-dislocation, and assuring a proper fixation, using a bilateral transpedicular screw-rod fixation system. Neurological improvement occurred in 9 cases of the 18 who had neurological deficit at admission. According to Frankel's criteria, these patients had an average of 1.125 Frankel's grade improvement; three of these patients recovered completely. There were no operative or postoperative deaths. Major complications included one case of major postoperative gastrointestinal bleeding, one case of pulmonary emboli, and two cases of deep wound infections. This study recommends the use of the Dick Internal Fixator for the correction of major spinal deformities due to its greater structural rigidity and greater availability of bone surfaces for fusion.
引用
收藏
页码:37 / 44
相关论文
共 50 条
  • [1] TRANSPEDICULAR SCREW-ROD FIXATION OF THE LUMBAR SPINE - OPERATIVE TECHNIQUE AND OUTCOME IN 104 CASES
    DICKMAN, CA
    FESSLER, RG
    MACMILLAN, M
    HAID, RW
    JOURNAL OF NEUROSURGERY, 1992, 77 (06) : 860 - 870
  • [2] Biomechanics of Lumbar Cortical Screw-Rod Fixation Versus Pedicle Screw-Rod Fixation With and Without Interbody Support
    Perez-Orribo, Luis
    Kalb, Samuel
    Reyes, Phillip M.
    Chang, Steve W.
    Crawford, Neil R.
    SPINE, 2013, 38 (08) : 635 - 641
  • [3] Treatment of traumatic unstable thoracolumbar junction fractures with transpedicular screw fixation
    Riaz-ur-Rehman
    Azmatullah
    Azam, Farooq
    Mushtaq
    Shah, Mewat
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2011, 61 (10) : 1005 - 1008
  • [4] Adjacent-segment effects of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support
    Wangsawatwong, Piyanat
    Sawa, Anna G. U.
    Pereira, Bernardo de Andrada
    Lehrman, Jennifer N.
    O'Neill, Luke K.
    Turner, Jay D.
    Uribe, Juan S.
    Kelly, Brian P.
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 35 (03) : 263 - 269
  • [5] Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system
    Weise, Lutz
    Suess, Olaf
    Picht, Thomas
    Kombos, Theodoros
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2008, 1 : 33 - 39
  • [6] Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients
    J. Oertel
    W.-R. Niendorf
    N. Darwish
    H. W. S. Schroeder
    M. R. Gaab
    Acta Neurochirurgica, 2004, 146 : 771 - 777
  • [7] Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients
    Oertel, J
    Niendorf, WR
    Darwish, N
    Schroeder, HWS
    Gaab, MR
    ACTA NEUROCHIRURGICA, 2004, 146 (08) : 771 - 777
  • [8] CROSSED-SCREW FIXATION OF THE UNSTABLE THORACIC AND LUMBAR SPINE
    BENZEL, EC
    BALDWIN, NG
    JOURNAL OF NEUROSURGERY, 1995, 82 (01) : 11 - 16
  • [9] The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: A 3-year consecutive series
    Yue, JJ
    Sossan, A
    Selgrath, C
    Deutsch, LS
    Wilkens, K
    Testaiuti, M
    Gabriel, JP
    SPINE, 2002, 27 (24) : 2782 - 2787