Electrochemical behaviour and determination of niraparib using glassy carbon and boron-doped diamond electrodes

被引:0
|
作者
Samanci, Seyda Nur [1 ,2 ,3 ]
Ozcelikay-Akyildiz, Goksu [1 ]
Atici, Esen Bellur [4 ,5 ]
Ozkan, Sibel A. [1 ]
机构
[1] Ankara Univ, Fac Pharm, Analyt Chem Dept, Ankara, Turkiye
[2] Ankara Univ, Grad Sch Hlth Sci, Ankara, Turkiye
[3] Afyonkarahisar Hlth Sci Univ, Fac Pharm, Dept Analyt Chem, Afyonkarahisar, Turkiye
[4] DEVAHolding AS R&D Ctr, Tekirdag, Turkiye
[5] Gebze Tech Univ, Dept Chem, Kocaeli, Turkiye
关键词
Boron-doped diamond electrode; Differential pulse voltammetry; Electrochemical behaviour; Glassy carbon electrode; Niraparib; PIPERIDINE;
D O I
10.1016/j.diamond.2025.111964
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Niraparib tosylate (NPB) is a polyadenosine diphosphate (ADP)-ribose polymerase (PARP) inhibitor and is used to treat ovarian cancer patients with BRCA1/2 loss-of-function mutations. The objective of this study was to provide a comprehensive analysis of the electrochemical behaviour of NPB and to develop sensitive and rapid electroanalytical methods for the quantification of NPB. These methods were developed employing a glassy carbon electrode (GCE) and a boron-doped diamond electrode (BDDE). The influence of the supporting electrolyte and pH on the peak potentials and currents of NPB was investigated through the use of cyclic voltammetry (CV) and differential pulse voltammetry (DPV). At a concentration of 0.1 mM NPB, the highest voltammetric peak response was observed in 0.1 M H2SO4 using a GCE and 0.5 M H2SO4 using a BDDE. The bare BDDE exhibited a diffusion-controlled process, whereas the GCE demonstrated an adsorption-controlled process. Based on the results and the number of electrons transferred (similar to 2 electrons), it is hypothesised that the electrooxidation of NPB occurs either by oxidation of the piperidine moiety to 1-hydroxypiperidine (N-hydroxypiperidine) to give NPB-PIPERIDINOX or by oxidation of the 2H-indazole moiety to indazolone to give NPB-INDAZOLONE. Under optimal experimental conditions, calibration curves for NPB were obtained at 0.8-10 mu M, with a limit of detection (LOD) of 0.016 mu M, using the GCE with adsorptive stripping differential pulse voltammetry (AdSDPV), and 10-100 mu M with an LOD of 0.285 mu M using BDDE with DPV. A recovery study was conducted on a commercially available serum sample using the standard addition method for both electrodes. The results demonstrated excellent recoveries (98.93-102.85 %) and reproducibility, with a relative standard deviation (RSD) of <2.0 % (N = 5).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Electrochemical Behavior and Determination of Tolvaptan Using Glassy Carbon and Boron-Doped Diamond Electrodes
    Karadurmus, Leyla
    Atici, Esen Bellur
    Ozkan, Sibel A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (11)
  • [2] Electrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes
    Gumustas, Mehmet
    Ozkan, Sibel A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (01) : 189 - 203
  • [3] Electrochemical evaluation and determination of antiretroviral drug fosamprenavir using boron-doped diamond and glassy carbon electrodes
    Mehmet Gumustas
    Sibel A. Ozkan
    Analytical and Bioanalytical Chemistry, 2010, 397 : 189 - 203
  • [4] Microwave activation of electrochemical processes at glassy carbon and boron-doped diamond electrodes
    Sur, UK
    Marken, F
    Seager, R
    Foord, JS
    Chatterjee, A
    Coles, BA
    Compton, RG
    ELECTROANALYSIS, 2005, 17 (5-6) : 385 - 391
  • [5] Comparison of boron-doped electrodes for determination diamond and glassy carbon of procaine hydrochloride
    Wei, Min
    Zhou, Yanli
    Zhi, Jinfang
    Fu, Degang
    Einaga, Yasuaki
    Fujishima, Akira
    Wang, Xuemei
    Gu, Zhongze
    ELECTROANALYSIS, 2008, 20 (02) : 137 - 143
  • [6] Preparation and Electrochemistry of Boron-Doped Diamond Nanoparticles on Glassy Carbon Electrodes
    Cunci, Lisandro
    Cabrera, Carlos R.
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2011, 14 (03) : K17 - K19
  • [7] Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
    Niedzialkowski, P.
    Cebula, Z.
    Malinowska, N.
    Bialobrzeska, W.
    Sobaszek, M.
    Ficek, M.
    Bogdanowicz, R.
    Anand, J. Sein
    Ossowski, T.
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 308 - 314
  • [8] Sensitive determination and electrochemical evaluation of anticancer drug tofacitinib in pharmaceutical and biological samples using glassy carbon and boron-doped diamond electrodes
    Budak, Fatma
    Cetinkaya, Ahmet
    Kaya, S. Irem
    Atici, Esen Bellur
    Ozkan, Sibel A.
    DIAMOND AND RELATED MATERIALS, 2023, 133
  • [9] Electroanalytical investigation and determination of pefloxacin in pharmaceuticals and serum at boron-doped diamond and glassy carbon electrodes
    Uslu, Bengi
    Topal, Burcu Dogan
    Ozkan, Sibel A.
    TALANTA, 2008, 74 (05) : 1191 - 1200
  • [10] Detection of Heavy Metals Based on Boron-doped Diamond Nanograss Array, Boron-doped Diamond Film and Glassy Carbon Electrodes
    Wei, Min
    Zeng, Gao Ying
    Liu, Yong
    Lu, Qiyu
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (02) : 861 - 863