Evaluation of Metal Artifact Reduction software in Computed Tomography

被引:0
|
作者
Eslam M. [1 ]
Abdelaziz M. [2 ]
机构
[1] Medical Imaging and Nuclear Medicine Department, Kundiawa Genaral Hospital, Papua New
[2] Medical Imaging Department, Arab Contractors Hospitals, Cairo
来源
Eslam, Mamoun | 1600年 / Mashhad University of Medical Sciences卷 / 17期
关键词
Computed Tomography; Evaluation; Image Quality; Implants Sinovision;
D O I
10.22038/ijmp.2019.42734.1638.
中图分类号
学科分类号
摘要
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative reconstruction algorithm (IDREAM). Material and Methods: Water phantom with raw chicken leg underwent CT scan (Sinovision, Insitum 16) before (reference group (GPref) and after metal implantation: ((GPA (IDREAM without MAR) and GPB (IDREAM with MAR)). A total number of 30 patients [GP1 (instrumented spine (n=15)), GP2 (Brain clips (n=15))] underwent CT scan (Sinovision,Insitum 16). GP1 and GP2 were reconstructed using two procedures including IDREAM without MAR vs. 2: IDREAM with MAR. All images were evaluated using subjective and quantitative assessment. Results: In subjective image quality assessment, the scores of MAR images were higher than IDREAM images (P<0.05) as indicated by four radiologists. The absolute CT difference (ΔCT) and Artifact index (AI) demonstrated that MAR appeared to be superior for the reduction of metal artifacts (P<0.05). Conclusion: As evidenced by the obtained results, MAR software can be efficiently used for metal artifact reduction in computed tomography (instrumental spine and brain clips). © 2020 2020
引用
收藏
页码:298 / 302
页数:4
相关论文
共 50 条
  • [1] Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images
    Huang, V.
    Kohli, K.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3244 - 3244
  • [2] Normalized Metal Artifact Reduction (NMAR) in Computed Tomography
    Meyer, Esther
    Bergner, Frank
    Raupach, Rainer
    Flohr, Thomas
    Kachelriess, Marc
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3251 - +
  • [3] Normalized metal artifact reduction (NMAR) in computed tomography
    Meyer, Esther
    Raupach, Rainer
    Lell, Michael
    Schmidt, Bernhard
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2010, 37 (10) : 5482 - 5493
  • [4] Metal Artifact Reduction in Computed Tomography by Constrained Optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [5] Metal artifact reduction using mono-energy images combined with metal artifact reduction software in spectral computed tomography: a study on phantoms
    Sun, Xiaoli
    Zhao, Qingqing
    Sun, Pengtao
    Yao, Zhipeng
    Wang, Rengui
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (07) : 1515 - 1525
  • [6] Metal Artifact Reduction in Radiotherapy - Implementation of iMAR corrected Computed Tomography and clinical Evaluation
    Sabatino, M.
    Kretschmer, M.
    Kasch, A.
    Zimmermann, M.
    Clos, S.
    Heyden, S.
    Dahle, J.
    Wuerschmidt, F.
    Allianz, Radiologische
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S102 - S102
  • [7] Frequency split metal artifact reduction (FSMAR) in computed tomography
    Meyer, Esther
    Raupach, Rainer
    Lell, Michael
    Schmidt, Bernhard
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 1904 - 1916
  • [8] Metal Artifact Reduction by Morphological Image Filtering for Computed Tomography
    Rodriguez-Gallo, Yakdiel
    Orozco-Morales, Ruben
    Perez-Diaz, Marlen
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 219 - 222
  • [9] Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
    Lell, Michael M.
    Meyer, Esther
    Kuefner, Michael A.
    May, Matthias S.
    Raupach, Rainer
    Uder, Michael
    Kachelriess, Marc
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (07) : 415 - 421
  • [10] Adaptive Normalized Metal Artifact Reduction (ANMAR) in Computed Tomography
    Meyer, Esther
    Raupach, Rainer
    Schmidt, Bernhard
    Mahnken, Andreas H.
    Kachelriess, Marc
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2560 - 2565