Arrangement of the heat dissipation pipes of a water-cooled grate in a high-temperature environment

被引:0
|
作者
Jiang T. [1 ]
Liu H. [1 ]
Zhang Z. [2 ]
机构
[1] School of Mechanical Engineering, Tongji University, Shanghai
[2] Incineration center, Shanghai Environmental Sanitation Engineering Design Institute Co., Ltd., Shanghai
关键词
duct arrangement; heat burnout; heat dissipation performance; high calorific value; high temperature; municipal domestic waste; waste incineration; water-cooled grate;
D O I
10.11990/jheu.202203047
中图分类号
学科分类号
摘要
To avoid the possible thermal burnout of the grate during the incineration of high-calorific-value waste, the heat dissipation performance of three types of internal piping arrangement (folding type, wave type, and return type) under four different waste calorific values and four different cooling water flow rates was simulated and studied. A certain type of water-cooled grate is taken as the research object, with the same piping cross-section. The results show that the bending-type water-cooled grate is suitable for waste incinerators with a small variation of the waste calorific value, whereas the wave-type water-cooled grate is suitable for waste incinerators with a large variation of the waste calorific value. It has some reference value for the design of forced water-cooled grates in high-temperature environments. © 2023 Editorial Board of Journal of Harbin Engineering. All rights reserved.
引用
收藏
页码:370 / 378
页数:8
相关论文
共 16 条
  • [1] GAO Mingna, YIN Yilin, Research on environmental benefits of waste incineration power generation project [ J], IOP conference series: earth and environmental science, 300, 3, (2019)
  • [2] JIANG Tao, WANG Jiehua, LIU Haiyang, Et al., Research on the mixing and segregation phenomenon of municipal solid waste layer on mechanical grate, Journal of Hunan University (natural sciences), 49, 6, pp. 1-8, (2022)
  • [3] ZHANG Jiandong, Measures to improve the performance of grate for waste incineration, Chemical enterprise management, 19, pp. 57-60, (2021)
  • [4] REN Zhongshan, CHEN Ying, WANG Yongming, Et al., Analysis of influence of domestic waste classification on development of waste incineration power generation industry in China, Environmental engineering, 39, 6, pp. 150-153, (2021)
  • [5] OWENS E M, SZCZEPKOWSKI J., Advancements in grate cooling technology, Proceedings of 18th annual North American waste-to-energy conference, pp. 321-323, (2010)
  • [6] LYU Yukun, WEI Zhuang, GE Quanzhi, Et al., Research on the flow and heat transfer characteristics of a water-cooling plate in a heat dissipation system, Energy engineering, 118, 6, pp. 1855-1867, (2021)
  • [7] HAN Naiqing, LI Lei, FU Zhichen, Et al., Cooling technology and numerical simulation of waste incineration water-cooled grate, Journal of green science and technology, 22, pp. 209-211, (2019)
  • [8] YAN Mengfan, YU Zhihua, Technical summarization on water cooling grate in Japan, China environmental protection industry, 2, pp. 41-44, (2019)
  • [9] KIM S B, SONG D K., Numerical investigation on residence time of cooling water and surface temperature distribution of water-cooled grates, Journal of mechanical science and technology, 32, 3, pp. 1057-1061, (2018)
  • [10] KIM S B, SONG D K., Numerical investigation of the heat transfer performance of water-cooled incineration grates with various channel designs, Applied thermal engineering, 131, pp. 437-445, (2018)