Energy performance evaluation of a passive house built to Scottish Building standards

被引:0
|
作者
Bros-Williamson, J. [1 ]
Stinson, J. [1 ]
Currie, J. [1 ]
机构
[1] Scottish Energy Center, Institute for Sustainable Construction, School of Engineering and Built, Environment Edinburgh Napier University, Edinburgh, United Kingdom
关键词
Building regulations - Energy performance evaluations - Energy performance of buildings - Manufacturing firms - Passivhaus - Performance gaps - Social housing - Thermal Performance;
D O I
暂无
中图分类号
学科分类号
摘要
Ensuring that predic:ed (simulated) energy performance figures are realized once a building is in-use has been of growing concern since issues surrounding the 'performance gap' were realized in the mid 1990's [1]. Increasing energy demand and a decrease in thermal comfort with an added pressure on fuel poor occupants has questioned why some dwellings are not delivering their design expectations. In accordance with the Energy Performance of Buildings Directive (Directive 2010/31/EC, EPBD) [2], each EU member state is required to evaluate at design stage the energy performance of buildings. Following these predictions, it is expected that the completed building is constructed to a performance level which ultimately reflects the design model. There is, however, significant evidence to show that buildings are not achieving these aspirational energy requirements which often translates into higher energy bills for the occupant(s). This paper has evaluated the difference in energy demand at the design stage and early-occupation stage of two similar dwellings constructed in Scotland for a large social landlord. The dwellings were constructed side-by-side, built using a similar timber frame system fabricated by the same manufacturing firm. One dwelling was constructed to Passive House (Passivhaus) standards, the other in accordance to conventional 2010 Scottish Building Regulations. Furthermore, this paper presents insitu thermal envelope evaluation results that were measured at post-construction and early occupation stage. The early findings from this research have shown that energy figures obtained through real-time hourly data of space and water heating for the Passive House and the more conventionally designed house during the first year of occupation were 37% and 35% higher in energy consumption, respectively, than the predicted figures. Field test results have provided evidence to suggest that this increased demand is, in-part, due to some deficiencies of the thermal envelope. Other factors that influence the operation of the dwelling, for example building services efficiency, control systems and occupant behavior have also contributed to widening the performance gap. © 2015 IAHS.
引用
收藏
页码:225 / 236
相关论文
共 50 条
  • [1] Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
    Manzoor, Sabir
    Iqbal, M. Tariq
    Goodyear, David
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2020, 10 (03): : 1234 - 1245
  • [2] Evaluation on distributed renewable energy system integrated with a Passive House building using a new energy performance index
    Wang, Yang
    Kuckelkorn, Jens
    Li, Daoliang
    Du, Jiangtao
    [J]. ENERGY, 2018, 161 : 81 - 89
  • [3] Passive house optimization for Portugal: Overheating evaluation and energy performance
    Figueiredo, Antonio
    Kampf, Jerome
    Vicente, Romeu
    [J]. ENERGY AND BUILDINGS, 2016, 118 : 181 - 196
  • [4] BUILDING ENERGY PERFORMANCE STANDARDS
    GUTMAN, WE
    [J]. ASHRAE JOURNAL, 1980, 22 (06) : 5 - 5
  • [5] ENERGY PERFORMANCE STANDARDS FOR BUILDING
    ROSOFF, D
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 45 - 45
  • [6] Advanced Building Materials for Passive House and Energy Storage
    Kim, Sumin
    Chang, Jae D.
    Lim, Jae-Han
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2017, 2017
  • [7] Comparison of building performance between Conventional House and Passive House in the UK
    Liang, Xinxin
    Wang, Yaodong
    Royapoor, Mohammad
    Wu, Qibai
    Roskilly, Tony
    [J]. PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1823 - 1828
  • [8] Are the energy savings of the passive house standard reliable? A review of the as-built thermal and space heating performance of passive house dwellings from 1990 to 2018
    Johnston, David
    Siddall, Mark
    Ottinger, Oliver
    Peper, Soeren
    Feist, Wolfgang
    [J]. ENERGY EFFICIENCY, 2020, 13 (08) : 1605 - 1631
  • [9] Are the energy savings of the passive house standard reliable? A review of the as-built thermal and space heating performance of passive house dwellings from 1990 to 2018
    David Johnston
    Mark Siddall
    Oliver Ottinger
    Soeren Peper
    Wolfgang Feist
    [J]. Energy Efficiency, 2020, 13 : 1605 - 1631
  • [10] RESTAURANT BUILDING ENERGY PERFORMANCE STANDARDS
    POLEDOR, AP
    [J]. ACTIVITIES REPORT-RESEARCH AND DEVELOPMENT ASSOCIATES FOR MILITARY FOOD AND PACKAGING SYSTEMS INC, 1980, 32 (02): : 140 - 140