摘要
Aiming at the vibration leakage phenomenon of refrigeration system pipeline of a civil space equipment, the main leakage location was tested and analyzed. To obtain the cause of leakage, the finite element model of the fusion pipeline installation state was constructed, and modal vibration simulation analysis of the pipeline structure was carried out. Using three axial random response and harmonic response to simulate the actual vibration condition of the product. Under the actual vibration condition, the main stress concentration point of the designed structure is the joint of square tube and circular tube, and the maximum equivalent stress cloud and displacement cloud diagram of X-direction, Y-direction and Z-direction of the vibration of pipeline was obtained under vibration excitation. The main stress concentration point of the structure was the joint of square and circular tube, and the maximum three-direction stresses of the pipeline are 8.15 MPa, 9.19 MPa and 7.05 MPa, which are much lower than the yield strength (165 MPa) and tensile strength (235 MPa) of 6063 aluminum alloy material. The simulation results verify the rationality of the design and provide an effective method for pipeline optimization design in complex environment. © 2020, Politechnica University of Bucharest. All rights reserved.
引用
收藏
页码:113 / 124
相关论文
共 50 条
  • [1] Study of refrigerant leakage in refrigeration system
    Yang, Z
    Zhang, SG
    Tian, GS
    Liu, B
    Ma, YT
    JOURNAL OF FIRE SCIENCES, 2002, 20 (03) : 237 - 245
  • [2] Analysis of hot water pipeline system leakage
    Zorc, Borut
    Kosec, Borut
    Kosec, Ladislav
    Nagode, Ales
    ENGINEERING FAILURE ANALYSIS, 2013, 28 : 78 - 81
  • [3] The Leakage Identification and Location of Ship Pipeline System Based on Vibration Signal Processing
    Su, Pan
    Wu, JieChang
    Chang, Guanghui
    Liu, Shuyong
    Feng, Xuejiao
    COMPLEXITY, 2023, 2023
  • [4] Leakage Vibration Measurement on the Oil & Gas Pipeline
    Zhao Huijun
    Wu Weiqiang
    Wang Xiaobing
    Zhou Ning
    Wang Shuli
    ISTM/2011: 9TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, 2011, : 763 - 766
  • [5] Methodology for experimental analysis of pipeline system vibration
    Schroetter, Martin
    Trebuna, Frantisek
    Hagara, Martin
    Kalina, Matus
    MODELLING OF MECHANICAL AND MECHATRONICS SYSTEMS, 2012, 48 : 613 - 620
  • [6] Experimental study on the leakage identification for the buried gas pipeline via vibration signals
    Chen, Xiugang
    Liu, Cuiwei
    Xiao, Kang
    Liu, Wenjie
    Gu, Tao
    Li, Yuxing
    JOURNAL OF PIPELINE SCIENCE AND ENGINEERING, 2025, 5 (02):
  • [7] Analysis on Vibration Signal of Pipeline for Hydraulic Exciting System
    Wei Xiu-ye
    Zhang Hui-xian
    Lu Chun-yue
    Lu Zi-rong
    FOURTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2012), 2012, 8334
  • [8] Simulation Analysis of Ammonia Leakage and Dispersion in a Large-Scale Refrigeration System
    Cheng, Jianlu
    Hu, Kaiyong
    Shen, Jiang
    Jia, Lu
    Niu, Rui
    Yang, Zhaoxian
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2022, 18 (04): : 1049 - 1066
  • [9] Case 47: Refrigeration system vibration
    Sofronas, T.
    HYDROCARBON PROCESSING, 2008, 87 (11): : 119 - 119
  • [10] A NUMERICAL STUDY OF REFRIGERANT LEAKAGE FROM A PROPANE-BASED REFRIGERATION SYSTEM
    Zhang, Mingkan
    Sharma, Vishaldeep
    Fricke, Brian A.
    PROCEEDINGS OF ASME 2023 HEAT TRANSFER SUMMER CONFERENCE, HT2023, 2023,