Wearable Low-intensity Focused Ultrasound Therapy Rehabilitation Stickers

被引:0
|
作者
Pang Y. [1 ]
Gou J.-Q. [1 ]
Zhang C. [1 ]
Hou H.-Y. [1 ]
Wang H.-Q. [1 ]
机构
[1] Academy of Opto Engineering, Chongqing University of Posts and Telecommunications, Chongqing
关键词
Low intensity focused ultrasound; Rehabilitation stickers; Treatment of soft tissue injury; Ultrasound therapy; Wearable;
D O I
10.15918/j.tbit1001-0645.2019.s1.024
中图分类号
学科分类号
摘要
In this paper, a wearable low-intensity focused ultrasound therapy device was designed to treat human soft tissue injury, relieve pain, and speed up the condition. Firstly, a QI standard wireless charging module was used to provide energy for the entire device. And an integrated conversion circuit with high conversion rate was designed to convert the voltage from 3.3 V to 5 V, providing voltage for the driving circuit. Then the remote control device controlled by the nRF24L01 module was used to control the ultrasonic rehabilitation paste. The STM32L151 microcontroller combined with PID algorithm can produce 1 MHz PWM wave, and the control drive circuit can drive piezoelectric ceramic chip to produce frequency of 1 MHz, strength of 100 mW/cm2, 132 mW/cm2, 150 mW/cm2 three gears ultrasonic. The device possesses the characteristics, including small size, fast charging, light weight, low cost, no coupling agent, wearable, high electro-acoustic conversion efficiency. © 2019, Editorial Department of Transaction of Beijing Institute of Technology. All right reserved.
引用
收藏
页码:132 / 135
页数:3
相关论文
共 11 条
  • [1] Dai X., Computer nationality alert occupational diseases, Health Review, 3, pp. 24-25, (2016)
  • [2] Ke J., Office gen: do you have these ten occupational diseases, Happy Family, 12, pp. 58-59, (2015)
  • [3] Carlson E.J., Save A.V., Iii J.F.S., Et al., Low-intensity pulsed ultrasound treatment for scaphoid fracture nonunions in adolescents, Jnl Wrist Surg, 4, 2, pp. 115-120, (2015)
  • [4] He C., Li C., Clinicalstudy of ultrasonic treatment of lower cervical soft tissue lesion pain, China Health Standard Management, 8, 14, pp. 110-112, (2017)
  • [5] Jiang W., Jiang W., Guo Y., Et al., Ultrasound-guided subacromial bursa combined with intranodular sulcus injection in the treatment of scapulohumeral periarthritis, China Foreign Medical Treatment, 35, 27, (2016)
  • [6] Qian F., Yin J., Zhang H., Et al., The research and expectation on wearable health monitoring system, Chinese Journal of Medical Instrumentation, 39, 1, pp. 40-43, (2015)
  • [7] Rigby J.H., Taggart R.M., Stratton K.L., Et al., Intramuscular heating characteristics of multihour low-intensity therapeutic ultrasound, Journal of Athletic Training, 50, 11, (2015)
  • [8] Cheung K., Hume P., Maxwell L., Delayed onset muscle soreness: treatment strategies and performance factors, Sports Medicine, 33, 2, (2003)
  • [9] Lewis G.K., Sustained acoustic medicine: a novel long duration approach to biomodulation utilizing low intensity therapeutic ultrasound, Proc Spie, 9467, (2015)
  • [10] Langer M.D., Design and evaluation of a wearable self-applied therapeutic ultrasound device for chronic myofascial pain, Ultrasound in Medicine & Biology, 39, 8, pp. 1429-1439, (2013)