A predictor-corrector interior point method for optimal reactive power

被引:0
|
作者
Cheng, Junzhao [1 ]
Li, Shusen [1 ]
Cheng, Qiang [2 ]
机构
[1] State Grid Electric Power Research Institute, Wuhan 430074, China
[2] Xi'an Jiaotong University, Xi'an 710049, China
关键词
Linear programming - Numerical methods - Iterative methods - Electric load flow - Reactive power;
D O I
暂无
中图分类号
学科分类号
摘要
Reactive optimal power flow is a nonlinear large-scale optimization problem. Predictor-corrector interior pointer method (PCIP) shows excellence performance on this problem. In an iteration in conventional PCIP, the affine scaling direction is obtained in predictor step so as to evaluate the second order terms of taylor expansions for complementarity functions and obtain the corrector step further. In this paper, an improved partner of PCIP is proposed. The method is in a new rectangle coordination model. In this model, all KKT equations are transformed to quadratic or linear ones. The proposed method works in the similar way as conventional PCIP in predictor step, but it evaluates the second order terms of all the functions instead. Then it calculates the corrector step. Numerical tests are carried out and the results confirms the priority of the proposed method to conventional one.
引用
收藏
页码:152 / 157
相关论文
共 50 条
  • [1] A nonlinear predictor-corrector interior point method for reactive power optimization in power system
    Xu, Jin-Dong
    Ding, Xiao-Qun
    Qin, Zhen-Cheng
    Li, Chen
    Power System Technology, 2005, 29 (09) : 36 - 40
  • [2] Weighted Multiple Predictor-corrector Interior Point Method for Optimal Power Flow
    Xie, Liang
    Chiang, Hsiao-Dong
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2011, 39 (02) : 99 - 112
  • [3] Dynamic optimal power flow with decomposed predictor-corrector interior point method
    Liu, Fang
    Yan, Wei
    Xu, Guoyu
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2007, 31 (14): : 38 - 42
  • [4] A Enhanced Multiple Predictor-Corrector Interior Point Method for Optimal Power Flow
    Xie, Liang
    Chiang, Hsiao-Dong
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [5] Decomposed Predictor-Corrector Interior Point Method for Dynamic Optimal Power Flow
    Chung, C. Y.
    Yan, Wei
    Liu, Fang
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (03) : 1030 - 1039
  • [6] Pseudo DC optimal power flow based on simplified predictor-corrector interior point method
    Gao, Qin
    Wei, Zhinong
    Chen, Hongtao
    Sun, Guoqiang
    Sun, Yonghui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (08): : 87 - 91
  • [7] Predictor-corrector interior point algorithm for current-based optimal power flow
    Lin, Whei-Min
    Huang, Cong-Hui
    Zhan, Tung-Sheng
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 893 - +
  • [8] A new predictor-corrector method for optimal power flow
    Probst, Roy Wilhelm
    Leite Oliveira, Aurelio Ribeiro
    OPTIMIZATION AND ENGINEERING, 2015, 16 (02) : 335 - 346
  • [9] AC-DC optimal reactive power flow model via predictor-corrector primal-dual interior-point method
    Nie, Yonghui
    Du, Zhengchun
    Li, Jiang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (04) : 382 - 390
  • [10] The Mehrotra predictor-corrector interior-point method as a perturbed composite Newton method
    Tapia, R
    Zhang, Y
    Saltzman, M
    Weiser, A
    SIAM JOURNAL ON OPTIMIZATION, 1996, 6 (01) : 47 - 56