Guest Room Energy Management System

被引:0
|
作者
Kumpanon, Arpakorn Ping [1 ]
Greco, John [1 ]
Pahor, Robert [1 ]
Chai, Bradley [1 ]
Carrillo, Ruben [1 ]
Wyllie, David [1 ]
McGinley, Karen [1 ]
机构
[1] DNV GL, United States
关键词
Air conditioning - Data acquisition - Energy conservation - Energy management - Energy utilization - Thermostats;
D O I
10.1080/01998595.2015.11449892
中图分类号
学科分类号
摘要
Hotel guest room energy management (GREM) systems are widely used throughout the world and the United States. The market for GREM has especially increased in the state of Nevada where guest room occupancy schedules vary at a high rate. Guests often leave their air conditioning equipment running during their absence. The GREM system determines the physical presence of guests by detecting infrared body heat. When a guest has left a room for a specified period, the system takes control from the normal thermostat and resets the room's temperature to energy conserving levels. Thus, installation of GREM control systems has been shown to reduce unnecessary energy consumption in unoccupied guest rooms. DNV GL conducted a GREM study at two hotels and casinos in Las Vegas Valley utilizing the INNCOM product. The primary objective of this assessment is to compare the energy use of GREM technology with existing technology, a conventional thermostat control. The selected sites were categorized by NV Energy service territories and types of HVAC equipment. Two types of fan coil units (FCU) were selected for this study - 2-pipe and 4-pipe systems. Energy uses of the FCUs were measured in equal numbers of rooms with conventional thermostat control and GREM control. A data acquisition system was installed to record important parameters, such as supply/return temperatures of airside and waterside, relative humidity and fan power with one-minute intervals for an entire year. These parameters were then analyzed to gain insight into the behavior of the FCU performance. Conclusions are determined by the estimated prescriptive energy savings resulting from controlling the FCU in unoccupied guest rooms. The results will be used to assess the prescriptive incentive program the utility offers to their customers. While Nevada's climatic data are considered in this study, the conclusions are generally more applicable in the desert southwest portion of the United States. © Copyright Association of Energy Engineers (AEE).
引用
收藏
页码:50 / 65
相关论文
共 50 条
  • [1] Guest Room Comprehensive Information Management System
    Luan, Feng
    PROCEEDINGS OF THE 2015 3RD INTERNATIONAL CONFERENCE ON MANAGEMENT SCIENCE, EDUCATION TECHNOLOGY, ARTS, SOCIAL SCIENCE AND ECONOMICS (MSETASSE 2015), 2015, 41 : 1039 - 1043
  • [2] Application of CAN Bus in Hotel Guest Room Service and Management System
    熊云帆
    耿庆波
    Journal of Beijing Institute of Technology, 2003, (S1) : 25 - 28
  • [3] Application of CAN Bus in Hotel Guest Room Service and Management System
    熊云帆
    耿庆波
    Journal of Beijing Institute of Technology(English Edition), 2003, (English Edition) : 25 - 28
  • [4] Thermal Inertia: Towards An Energy Conservation Room Management System
    Pan, Dawei
    Yuan, Yi
    Wang, Dan
    Xu, Xiaohua
    Peng, Yu
    Peng, Xiyuan
    Wan, Peng-Jun
    2012 PROCEEDINGS IEEE INFOCOM, 2012, : 2606 - 2610
  • [5] A room management system
    Falkowski, C
    COOPERATIVE BUILDINGS: INTEGRATING INFORMATION, ORGANIZATION, AND ARCHITECTURE, 1998, 1370 : 219 - 229
  • [6] Guest room
    Janowicz, Marianna
    ARCHITECTURAL REVIEW, 2024, (1517) : 32 - 32
  • [7] Guest room
    Herbert, Martin
    ARTFORUM INTERNATIONAL, 2023, 62 (01): : 226 - 227
  • [8] THE GUEST ROOM
    Lyall, Sarah
    NEW YORK TIMES BOOK REVIEW, 2023, 128 : 7 - 7
  • [9] Jane in the Guest Room
    Habel, Jennifer
    SEWANEE REVIEW, 2019, 127 (01) : 17 - 17
  • [10] Energy Saving of a University Building Using a Motion Detection Sensor and Room Management System
    Lee, Jong-Won
    Kim, Young Il
    SUSTAINABILITY, 2020, 12 (22) : 1 - 17