Revised method for preparation of simulated body fluid for assessment of the apatite-forming ability of bioactive materials: proposal of mixing two stock solutions

被引:0
|
作者
Dong, Wanyu [1 ]
Matsukawa, Yuko [1 ]
Long, Yanglifu [1 ]
Hayashi, Yoshinao [1 ]
Nakamura, Jin [2 ]
Suzuki, Kazumasa [1 ]
Ohtsuki, Chikara [1 ]
机构
[1] Nagoya Univ, Grad Sch Engn, Furo Cho,Chikusa Ku, Nagoya 4648603, Japan
[2] Kyushu Inst Technol, Grad Sch Life Sci & Syst Engn, 2-4 Hibikino,Wakamatsu Ku, Kitakyushu, Fukuoka 8080196, Japan
关键词
Bioactive glass;
D O I
10.1039/d4ra07739c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Bioactive glasses and glass-ceramics exhibit osteoconductivity, which is the ability to form a direct bond with living bone tissue. This property is typically assessed by observing the formation of a hydroxyapatite layer in vitro using simulated body fluid (SBF), a solution designed to mimic the inorganic constituents of human blood plasma. SBF was developed by Kokubo et al. (T. Kokubo, H. Kushitani, S. Sakka, T. Kitsugi and T. Yamamuro, J. Biomed. Mater. Res., 1990, 24, 721-734), and its preparation and storage procedures are precisely regulated according to ISO 23317. However, despite following the regulations, SBF may precipitate during storage owing to local ion concentration fluctuations during preparation because it is a supersaturated solution of hydroxyapatite. The present study is focused on designing a preparation process that enhances the stability of SBF-type biomimetic solutions. Solutions with a nominal composition that is the same as that of SBF were prepared by mixing stock solutions containing calcium or phosphate ions separately. Depending on the preparation procedure, two types of solutions-modified biomimetic solution (mBS) and evolved biomimetic solution (eBS)-were proposed. To evaluate the stability of these solutions, variants with 1.5 times the concentration of the original solutions were prepared, and the prepared solutions were denoted as xSBF, xmBS, and xeBS (where x = 1.0 or 1.5). It was found that the formation of calcium phosphate precipitates in 1.5mBS and 1.5eBS was slower than that in 1.5SBF. Additionally, the precipitate in 1.5eBS exhibited a different morphology from hydroxyapatite precipitate, which may be due to a higher hydrogencarbonate concentration than that in 1.5SBF. eBS demonstrated increased stability and a higher concentration of carbonic acid species (carbonate ions) than SBF, while mBS showed increased stability with a lower carbonate concentration than SBF. The newly proposed routes allow the production of an aqueous solution supersaturated with hydroxyapatite as a conventional SBF that has the potential to evaluate apatite formation via in vitro examination under high initial stability.
引用
收藏
页码:38660 / 38667
页数:8
相关论文
共 20 条
  • [1] Effect of simulated body fluid formulation on orthopedic device apatite-forming ability assessment
    Nguyen, Alexander K.
    Nelson, Sarah B.
    Skoog, Shelby A.
    Jaipan, Panupong
    Petrochenko, Peter E.
    Kaiser, Aric
    Lo, Linh
    Moreno, Jose
    Narayan, Roger J.
    Goering, Peter L.
    Kumar, Girish
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2023, 111 (05) : 987 - 995
  • [2] Apatite-forming ability of niobium oxide gels in a simulated body fluid
    Miyazaki, T
    Kim, HM
    Kokubo, T
    Ohtsuki, C
    Nakamura, T
    JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 2001, 109 (11) : 929 - 933
  • [3] Apatite-forming ability of polymers with carboxy groups in simulated body fluid
    Kawashita, M.
    Nakao, M.
    Minoda, M.
    Miyamoto, T.
    Kim, H.-M.
    Kokubo, T.
    Nakamura, T.
    Key Engineering Materials, 2001, 192-195 : 697 - 700
  • [4] Apatite-forming ability of polymers with carboxy groups in simulated body fluid
    Kawashita, M
    Nakao, M
    Minoda, M
    Miyamoto, T
    Kim, HM
    Kokubo, T
    Nakamura, T
    BIOCERAMICS, 2000, 192-1 : 697 - 700
  • [5] Thermoreversible behavior of κ-carrageenan and its apatite-forming ability in simulated body fluid
    Kim, Ill Yong
    Iwatsuki, Ryota
    Kikuta, Koichi
    Morita, Yumi
    Miyazaki, Toshiki
    Ohtsuki, Chikara
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (07): : 1472 - 1476
  • [6] The apatite-forming ability of bioactive glasses - A comparative study in human serum and Kokubo's simulated body fluid
    Szewczyk, Adrian
    Skwira-Rucinska, Adrianna
    Osinska, Marta
    Prokopowicz, Magdalena
    CERAMICS INTERNATIONAL, 2024, 50 (23) : 51030 - 51042
  • [7] Apatite-forming ability of sodium-containing titania gels in a simulated body fluid
    Uchida, M
    Kim, HM
    Kokubo, T
    Nakamura, T
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2001, 84 (12) : 2969 - 2974
  • [8] Apatite-forming ability of bioactive poly(L-lactic acid)/grafted silica nanocomposites in simulated body fluid
    Yan, Shifeng
    Yin, Jingbo
    Cui, Lei
    Yang, Yan
    Chen, Xuesi
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 86 (01) : 218 - 224
  • [9] Apatite-forming ability of carboxyl group-containing polymer gels in a simulated body fluid
    Kawashita, M
    Nakao, M
    Minoda, M
    Kim, HM
    Beppu, T
    Miyamoto, T
    Kokubo, T
    Nakamura, T
    BIOMATERIALS, 2003, 24 (14) : 2477 - 2484
  • [10] Apatite-forming ability of glass-ceramics containing whitlockite and diopside in a simulated body fluid
    Kamitakahara, M
    Ohtsuki, C
    Kozaka, Y
    Tanihara, M
    Miyazaki, T
    BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 341 - 344