Highly sensitive fiber vector magnetic field sensor based on an open-cavity Mach-Zehnder interferometer filled with magnetic fluid

被引:0
|
作者
Wang, Guiyu [1 ]
Wu, Yao [1 ]
Guan, Xinhang [1 ]
Chen, Xuefeng [2 ]
Yu, Xiujuan [1 ,2 ]
机构
[1] College of Physical Science and Technology, Heilongjiang University, Harbin,150080, China
[2] Heilongjiang Provincial Key Laboratory of Metamaterials Physics and Device, Heilongjiang University, Harbin,150080, China
基金
中国国家自然科学基金;
关键词
Galvanomagnetic effects - Magnetic field measurement - Magnetic levitation - Magnetorheological fluids - Velocity measurement;
D O I
10.1016/j.sna.2024.116075
中图分类号
学科分类号
摘要
In this paper, we proposed and demonstrated a highly sensitive fiber vector magnetic field sensor utilizing an open-cavity Mach-Zehnder interferometer (MZI) filled with magnetic fluid. The MZI sensor was fabricated using large-offset splicing technique to form an open cavity, facilitating the easy introduction of magnetic fluid samples into the open cavity. The MZI sensor was then encapsulated in a glass capillary containing diluted magnetic fluid. As the applied magnetic field varies, the refractive index of the magnetic fluid undergoes a corresponding change, subsequently inducing a shift in the transmission spectrum of the MZI. By monitoring the wavelength shift of the transmission spectrum, we can accurately detect the intensity of the magnetic field. The proposed sensor can achieve vector magnetic field measurement because of the axially asymmetric open-cavity MZI. The maximum sensitivity to magnetic field direction is 0.260 nm/°. Notably, the proposed sensor achieves an ultrahigh sensitivity, reaching an value of −17.306 nm/mT within the range of 4 mT to 7 mT. In addition, a temperature sensitivity of 2.236 nm/℃ is obtained within the temperature range of 30 ℃ to 65 ℃. Given its advantages, including high sensitivity, compact size and low cost, our MZI sensor holds immense potential for diverse applications in magnetic field measurement. © 2024
引用
收藏
相关论文
共 50 条
  • [1] Highly sensitive magnetic field sensor using tapered Mach-Zehnder interferometer
    Chen, Hao
    Shao, Zhihua
    Zhang, Xuan
    Hao, Yongxin
    Rong, Qiangzhou
    [J]. OPTICS AND LASERS IN ENGINEERING, 2018, 107 : 78 - 82
  • [2] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    雷雪琴
    徐彦超
    于雅婷
    彭保进
    [J]. Optoelectronics Letters, 2019, 15 (01) : 43 - 47
  • [3] A novel optical fiber magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Luo, Yan
    Lei, Xueqin
    Shi, Fuquan
    Peng, Baojin
    [J]. OPTIK, 2018, 174 : 252 - 258
  • [4] Ultrasensitive magnetic field sensor based on an in-fiber Mach-Zehnder interferometer with a magnetic fluid component
    Li, Zhengyong
    Liao, Changrui
    Song, Jun
    Wang, Ying
    Zhu, Feng
    Wang, Yiping
    Dong, Xiaopeng
    [J]. PHOTONICS RESEARCH, 2016, 4 (05) : 197 - 201
  • [5] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Xue-qin Lei
    Yan-chao Xu
    Ya-ting Yu
    Bao-jin Peng
    [J]. Optoelectronics Letters, 2019, 15 : 43 - 47
  • [6] Fiber in-line magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Lei Xue-qin
    Xu Yan-chao
    Yu Ya-ting
    Peng Bao-jin
    [J]. OPTOELECTRONICS LETTERS, 2019, 15 (01) : 43 - 47
  • [7] Highly sensitive vector magnetic field sensors based on fiber Mach-Zehnder interferometers
    Shuhao, Cai
    Sergeev, Maksim
    Petrov, Andrey
    Varzhel, Sergey
    Sheng, Chuanxiang
    Li, Li
    [J]. OPTICS COMMUNICATIONS, 2022, 524
  • [8] High sensitivity magnetic field sensor based on a Mach-Zehnder interferometer and magnetic fluid
    Zeng, Li
    Sun, Xiaoyan
    Zhang, Limu
    Hu, Youwang
    Duan, Ji'an
    [J]. OPTIK, 2022, 249
  • [9] Multimode assisted open-cavity Mach-Zehnder interferometer
    Zhang, Hui
    Liu, Chuanxu
    Zhang, Meng
    Yang, Jiuru
    [J]. TWELFTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2021), 2021, 12057
  • [10] Highly Sensitive Temperature Fiber Sensor Based on Mach-Zehnder Interferometer
    Hsu, Jui-Ming
    Chen, Jian-Zhi
    Zheng, Wen-Hao
    [J]. FIBER AND INTEGRATED OPTICS, 2016, 35 (5-6) : 230 - 238