Time Efficiency and Ergonomic Assessment of a Robotic Wheelchair Transfer System

被引:0
|
作者
Satpute, Shantanu A. [1 ,2 ]
Uribe, Kaylee J. [1 ,2 ]
Olaore, Oluwatofunmi O. [1 ]
Iizuka, Minori [1 ]
McCumber Gandara, Ian C. [1 ,3 ]
Schoy, William J. [1 ]
Kulkarni, Rutuja A. [1 ,2 ]
Cooper, Rosemarie [1 ]
Koontz, Alicia M. [1 ]
Flaugh, Owen [1 ]
Cooper, Rory A. [1 ,2 ,3 ]
机构
[1] Univ Pittsburgh, Sch Hlth & Rehabil Sci, Dept VA Pittsburgh Healthcare Syst, Human Engn Res Labs, Pittsburgh, PA 15206 USA
[2] Univ Pittsburgh, Swanson Sch Engn, Dept Bioengn, Pittsburgh, PA 15261 USA
[3] US Mil Acad, Dept Elect Engn & Comp Sci, West Point, NY 10996 USA
基金
美国国家科学基金会;
关键词
disability; motion capture; inertial measurement units; biomechanics; caregivers; nurses; back pain; musculoskeletal injuries; assistive technology; LOW-BACK-PAIN; WORK-RELATED MUSCULOSKELETAL; RISK-FACTORS; CAREGIVERS; DISORDERS; INJURIES; OVERHEAD; TRUNK; TASKS; FLOOR;
D O I
10.3390/s24237558
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Caregivers experience high rates of occupational injuries, especially during wheelchair transfers, which often result in back pain and musculoskeletal disorders due to the physical demands of lifting and repositioning. While mechanical floor lifts, the current standard, reduce back strain, they are time-consuming and require handling techniques that subject caregivers to prolonged and repeated non-neutral trunk postures, increasing the risk of long-term back injuries. Aims: The aim was to assess the time efficiency and ergonomics of the powered personal transfer system (PPTS), a robotic transfer device designed for bed-to/from-wheelchair transfers. Methods: We evaluated transfers with the PPTS and mechanical lift with eight able-bodied participants who assisted with transfers between a bed and a wheelchair. Inertial measurement units (IMUs) were placed on participants to track their motion and assess trunk joint angles during transfers. Results: The PPTS significantly reduced the transfer time (144.31 s vs. 525.82 s, p < 0.001) and required significantly less range of motion for trunk flexion (p < 0.001), lateral bending (p = 0.008), and axial rotation (p = 0.001), all of which have been associated with back injuries. Additionally, the PPTS significantly reduced the time caregivers spent in non-neutral trunk postures, potentially lowering injury risks. Conclusions: These findings suggest that the PPTS improves transfer efficiency and caregiver safety, offering a promising alternative to the current standard of care for wheelchair-to/from-bed transfers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Perceptions and assessment of a novel robotic wheelchair transfer system
    Satpute, Shantanu A.
    Cooper, Rosemarie
    Candiotti, Jorge
    Duvall, Jonathan A.
    Gebrosky, Benjamin
    Grindle, Garrett
    Deepak, Nikitha
    Sivakanthan, Sivashankar
    Koontz, Alicia
    Cooper, Rory A.
    JOURNAL OF SPINAL CORD MEDICINE, 2024,
  • [2] Ergonomic evaluation of a wheelchair transportation securement system
    Ahmed, Madiha
    Campbell-Kyureghyan, Naira
    Frost, Karen
    Bertocci, Gina
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2012, 41 : 4924 - 4930
  • [3] Pose estimation and docking of robotic wheelchair to robotic transfer system for autonomous transfer aid of motor-disabled
    Kim, CH
    Kim, SJ
    Kim, BK
    ASSISTIVE TECHNOLOGY: FROM VIRTUALITY TO REALITY, 2005, 16 : 317 - 321
  • [4] Ergonomic Assessment of Robotic versus Thoracoscopic Thymectomy
    Taje, Riccardo
    Peer, Michael
    Gallina, Filippo Tommaso
    Ambrogi, Vincenzo
    Sharbel, Azzam
    Melis, Enrico
    Elia, Stefano
    Idit, Matot
    Facciolo, Francesco
    Patirelis, Alexandro
    Sorge, Roberto
    Pompeo, Eugenio
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [5] Development of Autonomous Robotic Wheelchair System
    Kim, Chong Hui
    Kim, Seong Jin
    Kim, Hyun-Sang
    Kim, Byung Kook
    PROMOTING INDEPENDENCE FOR OLDER PERSONS WITH DISABILITIES, 2006, 18 : 85 - 96
  • [6] Design of an Ergonomic Wheelchair Drive System for Improved Shoulder Biomechanics
    Fairhurst, Stuart
    Nickel, Eric
    Morin, Steve
    Goldish, Gary
    Hansen, Andrew
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (03):
  • [7] Clinical and Ergonomic Comparison Between a Robotic Assisted Transfer Device and a Mobile Floor Lift During Caregiver-Assisted Wheelchair Transfers
    Greenhalgh, Mark
    Blaauw, Eline
    Deepak, Nikitha
    St Laurent, Matthew
    Cooper, Rosemarie
    Bendixen, Roxanna
    Grindle, Garrett G.
    Koontz, Alicia M.
    Cooper, Rory A.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2022, 101 (06) : 561 - 568
  • [8] Ergonomic assessment of robotic general surgeons: a pilot study
    Dwyer, Anthony
    Huckleby, Jeremy
    Kabbani, Majid
    Delano, Angela
    De Sutter, Michelle
    Crawford, David
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (03) : 387 - 392
  • [9] Ergonomic assessment of robotic general surgeons: a pilot study
    Anthony Dwyer
    Jeremy Huckleby
    Majid Kabbani
    Angela Delano
    Michelle De Sutter
    David Crawford
    Journal of Robotic Surgery, 2020, 14 : 387 - 392
  • [10] The Control System Based on Extended BCI for a Robotic Wheelchair
    Voznenko, Timofei, I
    Chepin, Eugene, V
    Urvanov, Gleb A.
    8TH ANNUAL INTERNATIONAL CONFERENCE ON BIOLOGICALLY INSPIRED COGNITIVE ARCHITECTURES, BICA 2017 (EIGHTH ANNUAL MEETING OF THE BICA SOCIETY), 2018, 123 : 522 - 527