This study presents four different impeller designs to compare hydrodynamic forces. Numerical simulation studies are performed via computational fluid dynamics to specify and investigate the hydraulic forces impacting the impeller of the mixed-flow blood pump with a volute. The design point of this pump is that the flow rate is 5 L/min, the rotational speed is 8000 rpm, and the manometric head is 100 mmHg. The designed impellers are placed in the same volute and simulation studies are performed with the same mesh size (17.3 million cells) of the pumps. The simulation studies have been conducted in setting 1050 kg/m3 blood density, 35 cP fluid viscosity, and SST-kω turbulence model. Additionally, this study examines the changes in hydraulic forces and hydraulic efficiency with fluid viscosity. As a result of experimental simulation studies, the highest hydraulic efficiencies of 40.87% and 39.5% are achieved in the case of the shaftless-grooveless and shafted-grooveless impeller, respectively. The maximum axial forces are obtained from the pump with the shaftless-grooveless impeller. Whereas radial forces, maximum values are calculated in the pump with the shaftless-outer groove impeller for all flow rates. Finally, the wall shear stresses, which are important for blood pump designs, are evaluated and the maximum value of 227 Pa is observed in the pump impeller with a shaftless-grooved. © The Author(s) 2024.
引用
收藏
页码:894 / 907
相关论文
共 50 条
  • [1] Computational fluid dynamics of gap flow in a biocentrifugal blood pump
    Chua, LP
    Song, GL
    Yu, SCM
    Lim, TM
    [J]. ARTIFICIAL ORGANS, 2005, 29 (08) : 620 - 628
  • [2] Computational fluid dynamics analysis of the pump parameters in the helical flow pump
    Hosoda, Kyohei
    Ishii, Kohei
    Isoyama, Takashi
    Saito, Itsuro
    Inoue, Yusuke
    Ariyoshi, Kouki
    Ono, Toshiya
    Nakagawa, Hidemoto
    Imachi, Kou
    Kumagai, Hiroshi
    Abe, Yusuke
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (01) : 9 - 15
  • [3] Computational fluid dynamics analysis of the pump parameters in the helical flow pump
    Kyohei Hosoda
    Kohei Ishii
    Takashi Isoyama
    Itsuro Saito
    Yusuke Inoue
    Kouki Ariyoshi
    Toshiya Ono
    Hidemoto Nakagawa
    Kou Imachi
    Hiroshi Kumagai
    Yusuke Abe
    [J]. Journal of Artificial Organs, 2014, 17 : 9 - 15
  • [4] Computational fluid dynamics in fluid machinery and pump flow problems
    Tourlidakis, A
    Elder, RL
    [J]. FLUID MACHINERY FOR THE OIL, PETROCHEMICAL, AND RELATED INDUSTRIES, 1996, 1996 (04): : 107 - 121
  • [5] Investigation of the flow performance of a nutating blood pump by computational fluid dynamics
    Sartori-Montecroce, O
    Goubergrits, F
    Affeld, K
    [J]. ARTIFICIAL ORGANS, 2002, 26 (04) : 392 - 396
  • [6] Investigation of fluid dynamics within a miniature mixed flow blood pump
    Z. J. Wu
    R. K. Gottlieb
    G. W. Burgreen
    J. A. Holmes
    D. C. Borzelleca
    M. V. Kameneva
    B. P. Griffith
    J. F. Antaki
    [J]. Experiments in Fluids, 2001, 31 : 615 - 629
  • [7] Investigation of fluid dynamics within a miniature mixed flow blood pump
    Wu, ZJ
    Gottlieb, RK
    Burgreen, GW
    Holmes, JA
    Borzelleca, DC
    Kameneva, MV
    Griffith, BP
    Antaki, JF
    [J]. EXPERIMENTS IN FLUIDS, 2001, 31 (06) : 615 - 629
  • [8] An estimation method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis
    Yano, T
    Sekine, K
    Mitoh, A
    Mitamura, Y
    Okamoto, E
    Kim, DW
    Nishimura, I
    Murabayashi, S
    Yozu, R
    [J]. ARTIFICIAL ORGANS, 2003, 27 (10) : 920 - 925
  • [9] Computational fluid dynamics analysis of a centrifugal blood pump with washout holes
    Tsukamoto, Y
    Ito, K
    Sawairi, T
    Konishi, Y
    Yamane, T
    Nishida, M
    Masuzawa, T
    Tsukiya, T
    Endo, S
    Taenaka, Y
    [J]. ARTIFICIAL ORGANS, 2000, 24 (08) : 648 - 652
  • [10] Review on fluid forces and their action on centrifugal pump impeller
    Singh, Jashanpreet
    Hashmi, Abdul Wahab
    [J]. INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2024,