Metal magnetic memory testing signals of 45 carbon steel during static tension process

被引:0
|
作者
National Key Laboratory for Remanufacturing, Academy of Armed Forces Engineering, Beijing 100072, China [1 ]
不详 [2 ]
机构
来源
Cailiao Gongcheng | 2008年 / 8卷 / 77-80期
关键词
Magnetic storage - Magnetism - Carbon steel - Ferromagnetic materials - Tensile strength - Steel testing;
D O I
暂无
中图分类号
学科分类号
摘要
The variations of the magnetic intensity, Hp(y), on the direction perpendicular to the surface of 45 carbon steel tensile specimens with shaft-shaped geometry and three different dimensions were determined during the static tension testing by using the metal magnetic memory. The relationship between the tension stress σ and the absolute value of slope of Hp(y) curve |k| was investigated. In the full elastic range, experimental results showed that, when the dimension of the specimens was given, the magnitude of |k| increased with increasing the loading magnitude. However, near the yield limit in the plastic range, the slope reached a local maximum and then decreased. After abruption, an abrupt change in Hp(y) curve occurred near the fracture surface. When the dimensions of the specimens were different, the relationship between σ and |k| was significantly influenced by the length of the specimens. Results showed that with increasing of the specimen length, the magnitude of |k| decreased.
引用
收藏
相关论文
共 50 条
  • [1] Study on metal magnetic memory signals of low carbon steel under static tension test condition
    National Key Laboratory for Remanufacturing, Armored Force Engineering Institute, Beijing 100072, China
    不详
    Cailiao Gongcheng, 2006, 3 (40-43):
  • [2] Characteristics of metal magnetic memory signals of different steels under static tension
    Zhang Y.
    Gou R.
    Li J.
    Shen G.
    Frontiers of Mechanical Engineering in China, 2010, 5 (2): : 226 - 232
  • [3] Influence of tension and fatigue load on the low carbon steel magnetic memory signals
    National Key Laboratory for Remanufacturing of Armored Force Engineering Institute, Beijng 100072, China
    不详
    Zhongguo Jixie Gongcheng, 2006, 7 (742-745):
  • [4] Characteristics of magnetic memory signals for medium carbon steel under static tensile conditions
    尹大伟
    徐滨士
    董世运
    杨尚林
    董丽虹
    Journal of Central South University, 2005, (S2) : 107 - 111
  • [5] Characteristics of magnetic memory signals for medium carbon steel under static tensile conditions
    Da-wei Yin
    Bin-shi Xu
    Shi-yun Dong
    Shang-lin Yang
    Li-hong Dong
    Journal of Central South University of Technology, 2005, 12 : 107 - 111
  • [6] Characteristics of magnetic memory signals for medium carbon steel under static tensile conditions
    Yin, DW
    Xu, BS
    Dong, SY
    Yang, SL
    Dong, LH
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2005, 12 (2): : 107 - 111
  • [7] Experimental and theoretical analysis of metal magnetic memory signals in the stress concentration area of 45# steel under tensile testing
    Su, Hao
    Chen, Ming
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 46 (01) : 271 - 280
  • [8] Metal magnetic memory effect caused by static tension load in a case-hardened steel
    Shi, C. L.
    Dong, S. Y.
    Xu, B. S.
    He, P.
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2010, 322 (04) : 413 - 416
  • [9] Study on magnetic memory signals of medium carbon steel specimens with surface crack precut during loading process
    Dong Lihong
    Xu Binshi
    Dong Shiyun
    Ye Minghui
    Chen Qunzhi
    RARE METALS, 2006, 25 : 431 - 435