AutoFOX: An automated cross-modal 3D fusion framework of coronary X-ray angiography and OCT

被引:0
|
作者
Li, Chunming [1 ]
Qiao, Yuchuan [2 ]
Yu, Wei [1 ]
Li, Yingguang [3 ]
Chen, Yankai [1 ]
Fan, Zehao [1 ]
Wei, Runguo [1 ]
Yang, Botao [1 ]
Wang, Zhiqing [4 ]
Lu, Xuesong [5 ]
Chen, Lianglong [4 ]
Collet, Carlos [6 ]
Chu, Miao [1 ,7 ]
Tu, Shengxian [1 ,7 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200030, Peoples R China
[2] Fudan Univ, Inst Sci & Technol Brain Inspired Intelligence, Shanghai 201200, Peoples R China
[3] Kunshan Ind Technol Res Inst, Int Smart Med Devices Innovat Ctr, Suzhou, Peoples R China
[4] Fujian Med Univ, Dept Cardiol, Union Hosp, Fuzhou, Peoples R China
[5] South Cent Minzu Univ, Sch Biomed Engn, Wuhan 430074, Hubei, Peoples R China
[6] OLV Clin, Cardiovasc Ctr Aalst, Aalst, Belgium
[7] Univ Oxford, Dept Cardiovasc Med, Oxford OX3 9DU, England
关键词
Coronary artery disease; X-ray angiography; OCT; Deep learning-based alignment; 3D fusion; ENDOTHELIAL SHEAR-STRESS; INTRAVASCULAR ULTRASOUND; CO-REGISTRATION; RECONSTRUCTION; ARTERIES; ALIGNMENT; DISEASE;
D O I
10.1016/j.media.2024.103432
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Coronary artery disease (CAD) is the leading cause of death globally. The 3D fusion of coronary X-ray angiography (XA) and optical coherence tomography (OCT) provides complementary information to appreciate coronary anatomy and plaque morphology. This significantly improve CAD diagnosis and prognosis by enabling precise hemodynamic and computational physiology assessments. The challenges of fusion lie in the potential misalignment caused by the foreshortening effect in XA and non-uniform acquisition of OCT pullback. Moreover, the need for reconstructions of major bifurcations is technically demanding. This paper proposed an automated 3D fusion framework AutoFOX, which consists of deep learning model TransCAN for 3D vessel alignment. The 3D vessel contours are processed as sequential data, whose features are extracted and integrated with bifurcation information to enhance alignment via a multi-task fashion. TransCAN shows the highest alignment accuracy among all methods with a mean alignment error of 0.99 +/- 0.81 mm along the vascular sequence, and only 0.82 +/- 0.69 mm at key anatomical positions. The proposed AutoFOX framework uniquely employs an advanced side branch lumen reconstruction algorithm to enhance the assessment of bifurcation lesions. A multi-center dataset is utilized for independent external validation, using the paired 3D coronary computer tomography angiography (CTA) as the reference standard. Novel morphological metrics are proposed to evaluate the fusion accuracy. Our experiments show that the fusion model generated by AutoFOX exhibits high morphological consistency with CTA. AutoFOX framework enables automatic and comprehensive assessment of CAD, especially for the accurate assessment of bifurcation stenosis, which is of clinical value to guiding procedure and optimization.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] 3D x-ray angiography
    Hoffmann, K
    MEDICAL PHYSICS, 2002, 29 (06) : 1278 - 1278
  • [2] Cross-Modal Center Loss for 3D Cross-Modal Retrieval
    Jing, Longlong
    Vahdani, Elahe
    Tan, Jiaxing
    Tian, Yingli
    2021 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, CVPR 2021, 2021, : 3141 - 3150
  • [3] 3D RECONSTRUCTION OF CORONARY ARTERIES FROM ROTATIONAL X-RAY ANGIOGRAPHY
    Oueslati, Chaima
    Mabrouk, Sabra
    Ghorbel, Faouzi
    Bedoui, Mohamed Hedi
    26. INTERNATIONAL CONFERENCE IN CENTRAL EUROPE ON COMPUTER GRAPHICS, VISUALIZATION AND COMPUTER VISION (WSCG 2018), 2018, 2802 : 64 - 69
  • [4] 3D RECONSTRUCTION OF CORONARY ARTERIES FROM ROTATIONAL X-RAY ANGIOGRAPHY
    Cardenes, Ruben
    Novikov, Alexey
    Gunn, Julian
    Hose, Rod
    Frangi, Alejandro F.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 618 - 621
  • [5] Automated registration of 3D X-ray angiography images to magnetic resonance images
    Kerrien, E
    Lévrier, O
    Anxionnat, R
    Sauty, S
    Knoplioch, J
    MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 623 - 632
  • [6] 3D Volume Reconstruction from Single Lateral X-Ray Image via Cross-Modal Discrete Embedding Transition
    Jiang, Yikun
    Li, Peixin
    Zhang, Yungeng
    Pei, Yuru
    Guo, Yuke
    Xu, Tianmin
    Yuan, Xiaoru
    MACHINE LEARNING IN MEDICAL IMAGING, MLMI 2020, 2020, 12436 : 322 - 331
  • [7] Functional Assessment of Stenotic Coronary Artery in 3D Geometric Reconstruction From Fusion of Intravascular Ultrasound and X-Ray Angiography
    Wang, Xiaoqing
    Peng, Changnong
    Liu, Xin
    Pan, Zhigeng
    IEEE ACCESS, 2018, 6 : 53330 - 53341
  • [8] Knowledge-Guided Cross-Modal Alignment and Progressive Fusion for Chest X-Ray Report Generation
    Huang, Lili
    Cao, Yiming
    Jia, Pengcheng
    Li, Chenglong
    Tang, Jin
    Li, Chuanfu
    IEEE TRANSACTIONS ON MULTIMEDIA, 2025, 27 : 557 - 567
  • [9] 3D modeling of the vessels from X-ray angiography
    Lee, Na-Young
    Kim, Gye-Young
    Choi, Hyung-Il
    DIGITAL HUMAN MODELING, 2007, 4561 : 646 - 654
  • [10] Cross-modal 3D Shape Generation and Manipulation
    Cheng, Zezhou
    Chai, Menglei
    Ren, Jian
    Lee, Hsin-Ying
    Olszewski, Kyle
    Huang, Zeng
    Maji, Subhransu
    Tulyakov, Sergey
    COMPUTER VISION - ECCV 2022, PT III, 2022, 13663 : 303 - 321