Activity measurement of 88Y by 4π(PPC)X-γ digital coincidence counting method

被引:0
|
作者
机构
[1] [1,Zheng, Yan-Ming
[2] Wang, Jian-Qing
[3] Yao, Shun-He
[4] Yang, Qiao-Ling
[5] Yao, Yan-Ling
来源
Zheng, Y.-M. | 1600年 / Atomic Energy Press卷 / 47期
关键词
Argon;
D O I
10.7538/yzk.2013.47.09.1483
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 26 条
  • [1] Activity determination of 88Y by means of 4πβ(LS)-γ coincidence counting
    Justyna Marganiec-Gałązka
    Ole J. Nähle
    Karsten Kossert
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 314 : 599 - 604
  • [2] Activity determination of 88Y by means of 4πβ(LS)-γ coincidence counting
    Marganiec-Galazka, Justyna
    Naehle, Ole J.
    Kossert, Karsten
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 314 (02) : 599 - 604
  • [3] 4π(PPC)X-γ数字符合法测量88Y活度
    郑艳明
    汪建清
    姚顺和
    杨巧玲
    姚艳玲
    原子能科学技术, 2013, 47 (09) : 1483 - 1487
  • [4] Digital coincidence counting with 4πβ(PPC)-γ for the standardization of 60Co
    Han, Minji
    Hwang, Sanghoon
    Agusbudiman, Agung
    Lee, J. M.
    Lee, K. B.
    Kim, B. C.
    Heo, D. H.
    Kim, T. H.
    APPLIED RADIATION AND ISOTOPES, 2024, 205
  • [5] DETERMINATION OF THE ACTIVITY CONCENTRATION OF A I-125 SOLUTION BY X-(X,GAMMA) COINCIDENCE COUNTING AND AN EFFICIENCY EXTRAPOLATION CURVE
    IWAHARA, A
    MARECHAL, MHH
    DASILVA, CJ
    POLEDNA, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (03): : 370 - 374
  • [6] Evaluation of absolute measurement using a 4π plastic scintillator for the 4πβ-γ coincidence counting method
    Unno, Y.
    Sanami, T.
    Sasaki, S.
    Hagiwara, M.
    Yunoki, A.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 302 - 306
  • [7] Standardization of 75Se by 4π(c, x)-γ coincidence counting method
    Park, T.S.
    Kim, I.S.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, 312 (1-2):
  • [8] A BI4π COUNTING METHOD FOR THE MEASUREMENT OF ACTIVITY
    于凤翘
    周宝国
    孙安康
    李作前
    Nuclear Science and Techniques, 1990, (03) : 179 - 186
  • [9] Accurate activity measurement of Lu-177 by the liquid scintillation 4πβ-γ coincidence counting technique
    Simpson, B. R. S.
    van Staden, M. J.
    Lubbe, J.
    van Wyngaardt, W. M.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2209 - 2214
  • [10] ABSOLUTE MEASUREMENT OF ACTIVITY OF 198AU FOILS USING THE 4πβ-γ COINCIDENCE COUNTING METHOD AND CORRECTIONS BY THE MONTE CARLO SIMULATION
    Nishiyama, Jun
    Harano, Hideki
    Matsumoto, Tetsuro
    Sato, Yasushi
    Uritani, Akira
    Kudo, Katsuhisa
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (02) : 237 - 241