Comparison of kinematic and kinetic parameters calculated using a cluster-based model and Vicon's plug-in gait

被引:0
|
作者
机构
[1] Duffell, Lynsey D.
[2] Hope, Natalie
[3] McGregor, Alison H.
来源
Duffell, Lynsey D. (l.duffell@imperial.ac.uk) | 1600年 / SAGE Publications Ltd卷 / 228期
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
Decision making - Joints (anatomy);
D O I
暂无
中图分类号
学科分类号
摘要
Gait analysis is an important clinical tool. A variety of models are used for gait analysis, each yielding different results. Errors in model outputs can occur due to inaccurate marker placement and skin motion artefacts, which may be reduced using a cluster-based model. We aimed to compare a custom-made cluster model (ClusBB) with Vicon's plug-in gait. A total of 21 healthy subjects wore marker sets for the ClusBB and plug-in gait models simultaneously while walking on a 6-m walkway. Marker and force plate data were captured synchronously and joint angles/moments were calculated using both models. There was good correlation between the models (coefficient of multiple correlations > 0.65) and good intra-session correlation for both models (coefficient of multiple correlations > 0.80). Inter-subject variability was high, ranging from 15°to 40°in the sagittal plane and 11°to 52°in the coronal and transverse planes. Intra-subject variability was small for both ClusBB and plug-in gait models. Inter-subject variance tended to be high in both models for knee abduction/adduction, but particularly so for plug-in gait, suggesting that a cluster-based model may reduce the variability. The inter-subject variance in out-of-sagittal plane data is of particular importance clinically, given the reliance on these datasets in clinical decision-making. © IMechE 2014.
引用
收藏
相关论文
共 10 条
  • [1] Comparison of kinematic and kinetic parameters calculated using a cluster-based model and Vicon's plug-in gait
    Duffell, Lynsey D.
    Hope, Natalie
    McGregor, Alison H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (02) : 206 - 210
  • [2] Comparison of kinematic and kinetic parameters calculated using a clusterbased model and Vicon's plug-in gait
    Duffell, L.D. (l.duffell@imperial.ac.uk), 1600, SAGE Publications Ltd (228):
  • [3] Kinematic analysis of gait in an underwater treadmill using land-based Vicon T 40s motion capture cameras arranged externally
    Raghu, Shreyas Lakshmipuram
    Conners, Ryan T.
    Kang, Chang-kwon
    Landrum, David Brian
    Whitehead, Paul N.
    JOURNAL OF BIOMECHANICS, 2021, 124
  • [4] Cluster-based upper body marker models for three-dimensional kinematic analysis: Comparison with an anatomical model and reliability analysis
    Boser, Quinn A.
    Valevicius, Aida M.
    Lavoie, Ewen B.
    Chapman, Craig S.
    Pilarski, Patrick M.
    Hebert, Jacqueline S.
    Vette, Albert H.
    JOURNAL OF BIOMECHANICS, 2018, 72 : 228 - 234
  • [5] Trip based optimal power management of plug-in hybrid electric vehicles using gas-kinetic traffic flow model
    Gong, Qiuming
    Li, Yaoyu
    Peng, Zhong-Ren
    2008 AMERICAN CONTROL CONFERENCE, VOLS 1-12, 2008, : 3225 - +
  • [6] A strathclyde cluster model for gait kinematic measurement using functional methods: a study of inter-assessor reliability analysis with comparison to anatomical models
    Meng, Lin
    Millar, Lindsay
    Childs, Craig
    Buis, Arjan
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (12) : 844 - 853
  • [7] A Comparison of the Conventional PiG Marker Method Versus a Cluster-Based Model when recording Gait Kinematics in Trans-Tibial Prosthesis Users and the Implications for Future IMU Gait Analysis
    Samala, Manunchaya
    Rowe, Philip
    Rattanakoch, Jutima
    Guerra, Gary
    SENSORS, 2020, 20 (05)
  • [8] A Cluster-based Model Using Functional Methods Requires Less Operator Experience for Reliable Gait Analysis: A Preliminary Study of Intra- and Inter-assessor Reliability
    Meng, Lin
    Millar, Lindsay
    Child, Craig
    Buis, Arjan
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 3154 - 3157
  • [9] Multi-hop Energy-Efficient Reliable Cluster-based Sectoring Scheme Using Markov Chain Model to Improve QoS Parameters in a WSN
    Wategaonkar, Dhanashri Narayan
    Nagaraj, S. V.
    Reshmi, T. R.
    WIRELESS PERSONAL COMMUNICATIONS, 2021, 119 (01) : 393 - 421
  • [10] Multi-hop Energy-Efficient Reliable Cluster-based Sectoring Scheme Using Markov Chain Model to Improve QoS Parameters in a WSN
    Dhanashri Narayan Wategaonkar
    S. V. Nagaraj
    T. R. Reshmi
    Wireless Personal Communications, 2021, 119 : 393 - 421