In vivo ultrahigh-resolution optical coherence tomography of mouse colon with an achromatized endoscope

被引:0
|
作者
University of Arizona, Division of Biomedical Engineering, Tuczon, AZ 85721, United States [1 ]
不详 [2 ]
不详 [3 ]
不详 [4 ]
机构
来源
J Biomed Opt | 2006年 / 6卷
基金
奥地利科学基金会; 美国国家卫生研究院;
关键词
Animals - Catheters - Diseases - Endoscopy - Medical imaging - Microscopic examination;
D O I
暂无
中图分类号
学科分类号
摘要
Endoscopic ultrahigh-resolution optical coherence tomography (OCT) enables collection of minimally invasive cross-sectional images in vivo, which may be used to facilitate rapid development of reliable mouse models of colon disease as well as assess chemopreventive and therapeutic agents. The small physical scale of mouse colon makes light penetration less problematic than in other tissues and high resolution acutely necessary. In our 2-mm diameter endoscopic time domain OCT system, isotropic ultrahigh-resolution is supported by a center wavelength of 800 nm and full-width-at-half-maximum bandwidth of 150 nm (mode-locked titanium:sapphire laser) combined with 1:1 conjugate imaging of a small core fiber. A pair of KZFSN5/SFPL53 doublets provides excellent color correction to support wide bandwidth throughout the imaging depth. A slight deviation from normal beam exit angle suppresses collection of the strong back reflection at the exit window surface. Our system achieves axial resolution of 3.2 μm in air and 4.4-μm lateral spot diameter with 101-dB sensitivity. Microscopic features too small to see in mouse tissue with conventional resolution systems, including colonic crypts, are clearly resolved. Resolution near the cellular level is potentially capable of identifying abnormal crypt formation and dysplatic cellular organization. © 2006 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
相关论文
共 50 条
  • [1] In vivo ultrahigh-resolution optical coherence tomography of mouse colon with an achromatized endoscope
    University of Arizona, Division of Biomedical Engineering, 1230 E. Speedway Blvd., Tucson, AZ 85721-0104, United States
    不详
    不详
    [J]. J Biomed Opt, 2006, 6
  • [2] In vivo ultrahigh-resolution optical coherence tomography of mouse colon with an achromatized endoscope
    Tumlinson, Alexandre R.
    Povazay, Boris
    Hariri, Lida P.
    McNally, James
    Unterhuber, Angelika
    Hermann, Boris
    Sattmann, Harald
    Drexler, Wolfgang
    Barton, Jennifer K.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (06)
  • [3] Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography
    Herz, PR
    Chen, Y
    Aguirre, AD
    Schneider, K
    Hsiung, P
    Fujimoto, JG
    Madden, K
    Schmitt, J
    Goodnow, J
    Petersen, C
    [J]. OPTICS LETTERS, 2004, 29 (19) : 2261 - 2263
  • [4] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    [J]. OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [5] In vivo ultrahigh-resolution, functional optical coherence tomography
    Drexler, W.
    Morgner, U.
    Kaertner, F.
    Ghanta, R.K.
    Pitris, C.
    Li, X.
    Ippen, E.P.
    Fujimoto, J.G.
    [J]. Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest, 2000, : 416 - 418
  • [6] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [7] Ultrahigh-resolution optical coherence tomography in glaucoma
    Wollstein, G
    Paunescu, LA
    Ko, TH
    Fujimoto, JG
    Kowalevicz, A
    Hartl, I
    Beaton, S
    Ishikawa, H
    Mattox, C
    Singh, O
    Duker, J
    Drexler, W
    Schuman, JS
    [J]. OPHTHALMOLOGY, 2005, 112 (02) : 229 - 237
  • [8] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    [J]. NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [9] Ultrahigh-resolution ophthalmic optical coherence tomography
    Wolfgang Drexler
    Uwe Morgner
    Ravi K. Ghanta
    Franz X. Kärtner
    Joel S. Schuman
    James G. Fujimoto
    [J]. Nature Medicine, 2001, 7 : 502 - 507
  • [10] Endoscope-tip interferometer for ultrahigh resolution frequency domain optical coherence tomography in mouse colon
    Tumlinson, AR
    Barton, JK
    Povazay, B
    Sattman, H
    Unterhuber, A
    Leitgeb, RA
    Drexler, W
    [J]. OPTICS EXPRESS, 2006, 14 (05) : 1878 - 1887