On-line insulation monitoring of substation DC power supply

被引:0
|
作者
Liupanshui Power Supply Bureau, Liupanshui 553000, China [1 ]
不详 [2 ]
机构
来源
关键词
Bandpass filters - Leakage currents - Electric grounding - Insulation - Intelligent control;
D O I
暂无
中图分类号
学科分类号
摘要
The disadvantages of present insulation monitoring of substation DC power supply system are pointed out and an online insulation monitoring method based on intelligent sensor and zero-crossing filter is proposed for DC power supply. The fault leakage current is detected by the intelligent sensors installed on every power supply circuits, and then sent to the monitoring computer via communication networks, which are processed by zero-crossing filter to eliminate the interference components. The grounding circuit and point are then effectively determined. The DC insulation variation of each branch is also monitored in real time and its downward trend is forecasted based on the historical data. The alarm criteria of instantaneous current limit violation and current change rate violation are put forward. The zero-crossing filter is also simulated. The validity of the proposed method is proved by on-site test.
引用
收藏
相关论文
共 50 条
  • [1] Improvement of On-line Monitoring Method for Insulation of Substation DC System
    Lei Xing
    Xu Nan
    Shen Wei
    Dai Chunyi
    Xu Zhaode
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2015, : 1350 - 1355
  • [2] Structure design of on-line monitoring system for power supply insulation
    Zhang Kai
    Hu Shunbin
    [J]. PROCEEDINGS OF THE 2007 INTERNATIONAL CONFERENCE ON AGRICULTURE ENGINEERING, 2007, : 340 - 344
  • [3] The new method of monitoring DC system insulation on-line
    Zhao, CY
    Jia, XF
    Hao, ZF
    [J]. IECON'01: 27TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2001, : 688 - 691
  • [4] The hardware design of a concentrative style on-line monitoring system for substation insulation
    Chen, Jidong
    Zhou, Long
    [J]. Gaoya Dianqi/High Voltage Apparatus, 2000, 36 (03): : 11 - 13
  • [5] On-line Partial Discharge Monitoring of Substation Power Transformers
    Huzmezan, Mihai
    [J]. 2022 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2022, : 347 - 352
  • [6] On-line monitoring system for leakage current of exterior insulation in power substation based on technology of virtual instrument
    Chen, Yu
    Qu, Bo
    Zhang, Shao-Feng
    Hu, Xue-Sheng
    Zhao, Yong
    Cheng, Yong-Hong
    [J]. Zhongguo Dianli/Electric Power, 2003, 36 (03):
  • [7] A novel distributing-collecting on-line insulation monitoring system and line selection technology for the DC supply system
    Feng, Chen
    Ye, Pingfeng
    Gao, Zhengzhong
    Jiang, Haiyang
    Zang, Xiangyu
    Zhang, Xiangxing
    [J]. FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [8] On-line monitoring technology for the insulation condition of capacitive-type substation equipment
    Hao, Xi-Wei
    Zhang, Guan-Jun
    Zhang, Wei
    Dong, Ming
    Liu, Guang-Yan
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1220 - +
  • [9] A novel insulation on-line monitoring and fault diagnosis system used for traction substation
    Zhang, GC
    Tong, XY
    Zou, SY
    Jiang, XW
    Wu, GN
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 199 - 202
  • [10] Study on insulation on-line monitoring expert system in substation based on neural network
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    [J]. Gaoya Dianqi, 2006, 2 (99-101):