Impedance modeling and resonance stability analysis of modular multilevel converter with power synchronization control

被引:0
|
作者
Lu Q. [1 ]
Yang Y. [1 ]
Zheng J. [1 ]
Li L. [1 ]
Guo H. [2 ]
Zhang Z. [2 ]
Xu Z. [2 ]
机构
[1] Power Dispatching Control Center of Guangdong Power Grid Corporation, Guangzhou
[2] College of Electrical Engineering, Zhejiang University, Hangzhou
关键词
harmonic state space; impedance modeling; modular multilevel converter; power synchronization control; resonance stability;
D O I
10.16081/j.epae.202206027
中图分类号
学科分类号
摘要
To investigate the impedance characteristics of PSC-MMC(Power Synchronization Control based on Modular Multilevel Converter) and the broadband resonance stability of the system with grid-connected PSC-MMC,utilizing harmonic state space method,considering the internal dynamic characteristics and complete control loops of MMC,an equivalent impedance model of PSC-MMC is built. The effects of newly employed power synchronization loop,reactive-voltage control and other major control loops on impedance characteristics in the power synchronization control are analyzed. The study has identified that PSC-MMC might have negative damping effect in subsynchronous frequency band and high frequency band,so there is a risk of causing resonance instability. Impedance scanning and electromagnetic transient simulation are carried out based on PSCAD/EMTDC,the simulative results respectively verify the accuracy of the model and stability analysis results. © 2022 Electric Power Automation Equipment Press. All rights reserved.
引用
收藏
页码:160 / 166
页数:6
相关论文
共 17 条
  • [1] LU Shaoqi, Zheng XU, Analysis of the maximum power flow in power synchronization control based MMC-HVDC[J], Proceedings of the CSEE, 36, 7, pp. 1868-1876, (2016)
  • [2] Lidong ZHANG, NEE H P., Power-synchronization control of grid-connected voltage-source converters[J], IEEE Transactions on Power Systems, 25, 2, pp. 809-820, (2010)
  • [3] Minyuan GUAN, Wulue PAN, Jing ZHANG, Et al., Synchronous generator emulation control strategy for Voltage Source Converter (VSC)stations[J], IEEE Transactions on Power Systems, 30, 6, pp. 3093-3101, (2015)
  • [4] Zheng XU, Physical mechanism and research approach of generalized synchronous stability for power systems[J], Electric Power Automation Equipment, 40, 9, pp. 3-9, (2020)
  • [5] Jian SUN, Impedance-based stability criterion for grid-connected inverters[J], IEEE Transactions on Power Electronics, 26, 11, pp. 3075-3078, (2011)
  • [6] ZHU Yiliang, GE Xinglai, Et al., Sequence admittance modeling and stability analysis for three-phase LCL-type grid-connected inverter with DC bus and MFC disturbance under weak grid[J], Electric Power Automation Equipment, 40, 9, pp. 190-203, (2020)
  • [7] LIU Zhenxiang, ZHAO Jinbin, ZENG Zhiwei, Et al., Small disturbance stability analysis of multi-converter DC microgrid based on impedance network model[J], Electric Power Automation Equipment, 41, 5, pp. 29-33, (2021)
  • [8] Jian SUN, Hanchao LIU, Sequence impedance modeling of modular multilevel converters[J], IEEE Journal of Emerging and Selected Topics in Power Electronics, 5, 4, pp. 1427-1443, (2017)
  • [9] Taiyuan YIN, Yue WANG, Bo YUE, Et al., Impedance-based stability analysis and stabilization control strategy of MMC-HVDC considering complete control loops[J], IEEE Access, 8, pp. 142900-142915, (2020)
  • [10] Jing LU, Xin ZHANG, Xu CAI, Et al., Harmonic state-space based small-signal impedance modeling of a modular multilevel converter with consideration of internal harmonic dynamics[J], IEEE Transactions on Power Electronics, 34, 3, pp. 2134-2148, (2019)