Study of the luminescent efficiency for narrow CsI (Tl) scintillator

被引:0
|
作者
Wei, Biao
Zhou, Mi
Jin, Donghuan
Feng, Peng
Mi, Deling
机构
[1] Key Lab. of Optoelectronic Technology and System, Department of Education, Chongqing 400044, China
[2] College of Chongqing Industry, Chongqing 400039, China
来源
Guangzi Xuebao/Acta Photonica Sinica | 2006年 / 35卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
An X-ray detector project, based on the narrow CsI (Tl) scintillating crystal and area-array CCD, using fiber optic and fiber optic plate as light coupled and transmission with fan-beam linear array scanning, has been put forth in this paper. Below 450 keV for x-ray energy, on the base of the physical analyzing and mathematical modeling, the luminescent efficiency property of narrow CsI (Tl) scintillation crystal has been studied by using Matlab. While the parameters of μph, μc, R, Rs, and σ equal to 0.00313, 0.0000295, 0.95, 0.8, and 0.000222 μm-1 respectively, it is concluded that the length range of the narrow CsI (Tl) scintillation crystal is 926-4512 μm, the height range is 242-5000 μm, and the width is 242-5000 μm. In the range of the above size, it can be obtained that space (or geometry) resolution of the narrow CsI (Tl) scintillation crystal is better and luminescent efficiency is also the highest.
引用
收藏
页码:41 / 46
相关论文
共 50 条
  • [1] A study on spatial resolution of pixelated CsI(Tl) scintillator
    Kim, Byoung-Jik
    Cha, Bo Kyung
    Jeon, Hosang
    Chi, Yong Ki
    Cho, Gyuseong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 205 - 207
  • [2] A New Columnar CsI(Tl) Scintillator for iQID detectors
    Han, Ling
    Miller, Brian W.
    Barber, H. Bradford
    Nagarkar, Vivek V.
    Furenlid, Lars R.
    [J]. MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [3] Image Restoration for CsI(Tl)-Scintillator Mammography Detectors
    Kim, Dong Sik
    Lee, Eunae
    [J]. 2019 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2019, : 432 - 433
  • [4] A Study of CsI(Tl) Scintillator with Optimized Conditions of Large Area Avalanche Photodiode
    Kim, Minjeong
    Kang, Heedong
    Kim, H. J.
    Kim, Wan
    Park, H.
    Kim, Sunghwan
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 586 - 589
  • [5] Response of the GAGG(Ce) scintillator to charged particles compared with the CsI(Tl) scintillator
    Furuno, T.
    Koshikawa, A.
    Kawabata, T.
    Itoh, M.
    Kurosawa, S.
    Morimoto, T.
    Murata, M.
    Sakanashi, K.
    Tsumura, M.
    Yamaji, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2021, 16 (10)
  • [6] Afterglow Suppression by Codoping with Bi in CsI:Tl Crystal Scintillator
    Totsuka, Daisuke
    Yanagida, Takayuki
    Fujimoto, Yutaka
    Yokota, Yuui
    Moretti, Federico
    Vedda, Anna
    Yoshikawa, Akira
    [J]. APPLIED PHYSICS EXPRESS, 2012, 5 (05)
  • [7] A theoretical study of CsI:Tl columnar scintillator image quality parameters by analytical modeling
    Kalyvas, N.
    Valais, I.
    Michail, C.
    Fountos, G.
    Kandarakis, I.
    Cavouras, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 779 : 18 - 24
  • [8] CsI: Tl scintillator separated by Si grid partition wall
    Tabata, Kento
    Nishizawa, Junichi
    Koike, Akihumi.
    Aoki, Toru
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVIII, 2016, 9968
  • [9] Characteristics of a Fabricated PIN Photodiode for a Matching With a CsI(Tl) Scintillator
    Kim, Han Soo
    Park, Se Hwan
    Ha, Jang Ho
    Lee, Dong-Hoon
    Cho, Seung Yeon
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 1382 - 1385
  • [10] Human subject portal images with a CsI(Tl) transparent scintillator
    Zeman, HD
    Samant, SS
    Sawant, A
    [J]. MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 682 - 693