Performance comparison of aerobic filter and deep bed equal coarse ceramic filter

被引:0
|
作者
Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology, Beijing 100022, China [1 ]
不详 [2 ]
机构
来源
Harbin Gongye Daxue Xuebao | 2007年 / 12卷 / 1979-1983期
关键词
Ammonia - Chemical oxygen demand - Nitrogen removal - Organic compounds;
D O I
暂无
中图分类号
学科分类号
摘要
To improve the removal efficiency of organics and ammonia nitrogen by filtration in advanced wastewater treatment process, air was supplied to filter bed via backwashing air distribution pipes during filtration. This kind of filter was called aerobic filter (AF) in this article. Contrast tests were done between AF and deep bed equal coarse ceramic filter (DF) with the same influent, which was the secondary effluent of a municipal wastewater treatment plant in north China. Results showed that, AF had high flexibility for the quality variation of influent. Chemical oxygen demand, ammonia nitrogen, turbidity and suspended solids in effluent of AF were lower than those in effluent of DF with the same influent during the most of test time. In contrast with DF, the worse the influent, the higher performance of AF was observed. Besides, the initial headloss of AF was higher than that of GF and the headloss increasing rate was higher too. Most headloss was distributed at the top bed for GF while the headloss of AF was distributed evenly along the bed profile. At the same operation condition, AF consumed shorter run time than GF.
引用
收藏
相关论文
共 50 条
  • [1] LiMCa comparison of a bed filter and a two stage ceramic foam filter
    Chesonis, DC
    DeYoung, DH
    Lake, DE
    Ridler, NR
    LIGHT METALS 2002, 2002, : 937 - 943
  • [2] BACKWASHING AND CONDITIONING OF A DEEP BED FILTER
    FRANCOIS, RJ
    VANHAUTE, AA
    WATER RESEARCH, 1985, 19 (11) : 1357 - 1362
  • [3] PREDICTION OF DEEP-BED FILTER PERFORMANCE USING RECURSIVE ALGORITHMS
    OJHA, CSP
    GRAHAM, NJD
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1994, 120 (04): : 961 - 971
  • [4] PERFORMANCE EVALUATION OF CERAMIC FILTER CANDLES
    CHAUDHURI, M
    VERMA, SR
    GUPTA, A
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1994, 120 (06): : 1646 - 1651
  • [5] MOVING BED FILTER PERFORMANCE STUDIES
    MIXON, FO
    CHEMICAL ENGINEERING PROGRESS, 1975, 71 (12) : 40 - 46
  • [6] EFFECT OF SHAPES OF FILTER MEDIA ON INITIAL FILTER COEFFICIENTS IN DEEP BED FILTRATION
    YOSHIMURA, Y
    FUKUMURA, K
    YOSHIOKA, N
    KAGAKU KOGAKU RONBUNSHU, 1980, 6 (06) : 657 - 659
  • [7] CERAMIC CANDLE FILTER PERFORMANCE AT THE GRIMETHORPE (UK) PRESSURIZED FLUIDIZED-BED COMBUSTOR
    STRINGER, J
    LEITCH, AJ
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1992, 114 (02): : 371 - 379
  • [8] Optimized design of a novel filter brick in denitrification deep-bed filter
    Huang, Hui
    Peng, Chong
    Li, Kai
    Wang, Qing
    Ren, Hongqiang
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2019, 42 (10) : 1701 - 1710
  • [9] Deep Bed Filtration Asymptotics at the Filter Inlet
    Kuzmina, Ludmila I.
    Osipov, Yuri V.
    XXV POLISH - RUSSIAN - SLOVAK SEMINAR -THEORETICAL FOUNDATION OF CIVIL ENGINEERING, 2016, 153 : 366 - 370
  • [10] A NEW SOLUTION OF THE DEEP BED FILTER EQUATIONS
    SAATCI, AM
    HALILSOY, M