Three-phase four-wire active load with performance of energy regeneration

被引:0
|
作者
Wu K.-D. [1 ]
Wu J.-C. [2 ]
Jou H.-L. [1 ]
Chen W.-C. [1 ]
机构
[1] Department of Electrical Engineering, National Kaohsiung University of Applied Sciences
[2] Department of Microelectronic Engineering, National Kaohsiung Marine University
来源
关键词
Active load; Energy regeneration; Power converter; Three-phase four-wire;
D O I
10.2316/Journal.203.2010.3.203-3935
中图分类号
学科分类号
摘要
In this paper, a three-phase four-wire active load capable of energy regeneration is proposed. The proposed active load comprises a load characteristic power converter, an energy regeneration power converter and a DC capacitor. The load characteristic power converter and the energy regeneration power converter are connected in series, and the DC capacitor acting as the energy buffer is located at the common dc bus of both power converters. The load characteristic power converter can be used to simulate a resistive load, a resistive/inductive load, a resistive/capacitive load and a rectifier load. The energy consumed by the load characteristic power converter will be regenerated back to the utility through the energy regeneration power converter. Moreover, the energy regeneration power converter also serves as an active power filter (APF) to suppress the harmonic current and compensate for the reactive power of the tested equipment. Hence, the utility supplies only a small real power to overcome the power loss of the active load and tested equipment. A prototype is developed and tested to verify the performance of the proposed active load. Experimental results show that the proposed active load can efficiently perform the expected function.
引用
收藏
页码:169 / 175
页数:6
相关论文
共 50 条
  • [1] Energy control of three-phase four-wire shunt active power filter
    Rodríguez, P
    Pindado, R
    Pou, J
    IECON'03: THE 29TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1 - 3, PROCEEDINGS, 2003, : 1061 - 1066
  • [2] Performance Analysis of Three-phase Four-wire Shunt Active Power Filter
    Vanjani, Harsha
    Choudhury, U. K.
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON RELIABILTY, OPTIMIZATION, & INFORMATION TECHNOLOGY (ICROIT 2014), 2014, : 496 - 500
  • [3] Modularized three-phase four-wire active power filter
    Kuo, Yu-Ting
    Chiueh, Ming-Hong
    Hsu, Wen
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1853 - 1858
  • [4] Novel Control Algorithm for Active Load Balancer in Three-Phase Four-Wire Distribution Systems
    Win, Tint Soe
    Hiraki, Eiji
    Okamoto, Masayuki
    Lee, Seong Ryong
    Tanaka, Toshihiko
    IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2014, 3 (03) : 286 - 287
  • [5] Four-wire three-phase load balancing with Static VAr Compensators
    Quintela, F. R.
    Areva, J. M. G.
    Redondo, R. C.
    Melchor, N. R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (03) : 562 - 568
  • [6] Design and Performance of a Shunt Active Power Filter for Three-phase Four-wire System
    Wu, Diyun
    Che, Yanbo
    Cheng, K. W. E.
    2009 3RD INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS: ELECTRIC VEHICLE AND GREEN ENERGY, 2009, : 88 - 88
  • [7] The Study of Three-Phase Four-Wire Shunt Active Power Filter
    Huang, Hai-hong
    Xu, Ruo-bing
    Wang, Hai-xin
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 3496 - 3499
  • [8] Active power filter used for three-phase four-wire system
    Zhuo, F
    Wang, Y
    Li, H
    Wang, Z
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 616 - 619
  • [9] Control of a three-phase four-wire active filter operating with an open phase
    Jacobina, CB
    Pinheiro, RF
    Correa, MBD
    Lima, AMN
    Da Silva, ERC
    CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 561 - 568
  • [10] Three-phase four-wire shunt active filter control strategies
    Aredes, M
    Hafner, J
    Heumann, K
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) : 311 - 318