Detecting Method of High Voltage Circuit Breaker Spring Fatigue Based on Vibration Signal

被引:0
|
作者
Dou L. [1 ,2 ]
He Y. [1 ,2 ]
Wan S. [1 ,2 ]
Zhang X. [1 ,2 ]
Wang X. [1 ,2 ]
机构
[1] Department of Mechanical Engineering, North China Electric Power University, Baoding
[2] Hebei Key Laboratory of Health Maintenance and Failure Prevention of Electrical Machinery and Equipment, Baoding
关键词
High voltage circuit breaker; nonlinear least square method; spring fatigue; vibration signal;
D O I
10.19595/j.cnki.1000-6753.tces.212014
中图分类号
学科分类号
摘要
Spring fatigue is a typical fault that frequently occurs in high-voltage circuit breakers. However, most traditional test methods cannot detect online. Therefore, a way to detect the spring fatigue fault based on vibration signals is proposed. Firstly, according to the working principle of the high-voltage circuit breaker, the energy transfer mechanism in the operation process is analyzed, and the whole structure is simplified into particle points. Then, after filtering the noise in the vibration signal, the equivalent energy distribution is calculated by constructing the kinetic energy function of each particle point. Finally, the energy transfer function of the high voltage circuit breaker is constructed by the nonlinear least square method to calculate the spring energy. The experimental results show that the detection error of the spring energy is within 2.2%, which verifies the effectiveness and accuracy of the proposed method. This method can provide a new way to detect spring fatigue in high-voltage circuit breakers. © 2022 Chinese Machine Press. All rights reserved.
引用
收藏
页码:6420 / 6430
页数:10
相关论文
共 29 条
  • [1] Wen Weijie, Li Pengyu, Li Bin, Et al., Operation strategy and parameter optimization of multi-port mechanical DC circuit breaker, Automation of Electric Power Systems, 45, 11, pp. 86-94, (2021)
  • [2] Wang Can, Du Chuan, Xu Jiexiong, Review of topologies for medium-and high-voltage DC circuit breaker, Automation of Electric Power Systems, 44, 9, pp. 187-199, (2020)
  • [3] Polycarpou A A, Soom A, Swarnakar V, Et al., Event timing and shape analysis of vibration bursts from power circuit breakers, IEEE Transactions on Power Delivery, 11, 2, pp. 848-857, (1996)
  • [4] Lee D W, Sohn J H, Yoo W S., Mass effect analysis of a coil spring for the performance evaluation of a gas insulated circuit breaker, International Journal of Precision Engineering and Manufacturing, 15, 12, pp. 2543-2548, (2014)
  • [5] Rudsari F N, Razi-Kazemi A A, Shoorehdeli M A., Fault analysis of high-voltage circuit breakers based on coil current and contact travel waveforms through modified SVM classifier, IEEE Transactions on Power Delivery, 34, 4, pp. 1608-1618, (2019)
  • [6] Lin Xin, Wang Feiming, Liu Weidong, Et al., Experiment researches on cold state dielectric recovery characteristics in high voltage SF<sub>6</sub> circuit breakers, Proceedings of the CSEE, 36, 14, pp. 3973-3981, (2016)
  • [7] Runde M, Ottesen G E, Skyberg B, Et al., Vibration analysis for diagnostic testing of circuit-breakers, IEEE Transactions on Power Delivery, 11, 4, pp. 1816-1823, (1996)
  • [8] Li Pengfei, Zhou Wenjun, Zeng Guo, Et al., The dynamic characteristics and energy storage state detection method of high-voltage circuit breaker closing spring, Transactions of China Electrotechnical Society, 31, 3, pp. 104-112, (2016)
  • [9] Yang Qiuyu, Peng Yanqing, Zhuang Zhijian, Dynamic simulation and failure analysis of spring mechanism of high-voltage circuit breaker based on ADAMS, High Voltage Apparatus, 54, 6, pp. 67-73, (2018)
  • [10] Su Yi, Lu Yufeng, Xie Zhibiao, Et al., Study on closing spring fatigue characteristics of high voltage circuit breaker, IOP Conference Series: Earth and Environmental Science, 508, 1, (2020)